Wright State University
Using Artificial Sweeteners Acesulfame (ACE K) To Trace Septic Leachate into Nutter Center Pond
Abstract
dc:descriptionThis research was carried out with a view to determining if the water flowing through Wright State University woods is contaminated and the source of the contamination. Four sample sites named OTF 15, BURLY, OTF 21 and Inflow into Nutter Center Pond (INNCP) were monitored and sampled from downstream to upstream over a period of nine months ranging from June 6, 2022, to February 13, 2023. Samples collected were analyzed for anions (phosphate, nitrate, sulfate, chloride and fluoride) using the Dionex ICS-600 ion chromatography. Water quality parameters were also measured using the YSI multimeter probe. After the analysis, not all anions were detected, the only two anions detected were chloride and sulfate in different concentrations. There is also a notable trend for the concentrations of sulfate and chloride on February 13, 2023, it was scary high. This could be attributed to the deicing salts used on the roads. Also comparing the data gotten from this analysis to the previous analysis and sampling done in the past for the same sample sites.Samples were also collected from the INNCP in a 500-mL amber glass bottle for analysis of ACE K. Artificial sweeteners are resistant to biodegradation, so they are potential tracers for tracking leachate from septic systems. On the Wright State Campus, Nutter Center Pond is potentially in the flow path of groundwater coming from septic systems in Bath township on the east side of Highway 844. Acesulfame (ACE-K) is an artificial sweetener that is highly resistant to biodegradation. It tastes sweet but does not metabolize, which is why it is resistant to biodegradation. Samples of surface water were collected over several months from a stream that flows under Highway 844 to the west into Nutter Center Pond. Samples were prepared using solid-phase extraction on an Oasis HLB cartridge and analyzed using liquid chromatography – mass spectrometry. The limit of detection for the instrument for ACE K was 1µg/L, and the concentration of the standard used for the calibration curve ranged from 100 µg/L to 1µg/L. Samples couldn’t be analyzed on the LC/MS, thereby making the results inconclusive.
Degree
thesis:*- Name thesis:degree_name
- Master of Science (MS)
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Chemistry
- Grantor dc:publisher
- Wright State University
- Year dc:date
- 2023
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Odoh, Israel Oluchukwu
- Advisor dc:contributor.advisor
-
- McGowin, Audrey E.
Subjects
dc:subject × 6Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=wright1693254176128625