Back to search

Wright State University

Biomechanical Simulation of Cardiovascular Implantable Electronic Device Leads with Residual Properties

Abstract

dc:description

Implantable leads used in pacemakers, defibrillators, and cardiac resynchronization therapy are designed for in-vivo applications, yet their longevity is inevitably shaped by the conditions within the human body. The mechanical behavior of these leads can be affected over time, necessitating the evaluation of their residual properties. Two main insulators, silicone, and polyurethane are commonly used for the outer insulation of cardiac leads. Understanding the long-term performance of these insulators is crucial for ensuring the reliability and safety of cardiac implantable devices. The research aims to assess the long-term mechanical properties and performance of implantable leads utilized in cardiovascular implantable electronic devices (CIEDs), which are subjected to the in-vivo environment with finite lifespans. Utilizing more than 300 samples obtained from the Wright State University Anatomical Gift Program. Tests were conducted according to ASTM standard D 1708-02a and ASTM Standard D 412-06a using the Test Resources Q series system. Electromagnetic interference (EMI) from electric vehicles on CIEDs, particularly Subcutaneous Implantable Cardioverter-Defibrillators (S-ICDs) were quantified within a Tesla Model 3. SolidWorks and MIMICS 25.0 were used for three-dimensional heart modeling, and were developed with CIED leads inside the heart for finite element analysis. ANSYS Workbench 2022R1 was utilized for simulating cardiac leads behavior inside the heart with specific residual properties, and used computational simulations to predict lead performance. This research found silicone insulation to show some degradation in mechanical properties after 94 months of in-vivo environment, and polyurethane insulation demonstrated consistent performance without significant degradation after 108 months of in-vivo exposure. The proposed mechanical testing and FEM provide an insight into the durability and performance of different insulation materials, and how these materials behave over time when exposed to physiological conditions within the body. From this perspective, we can enhance the durability of CIED leads, potentially extending their lifespan. This research holds promises in guiding future advancements in CIED lead design and ultimately enhancing patient outcomes in the field of cardiac rhythm management.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy (PhD)
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Engineering PhD
Grantor dc:publisher
Wright State University
Year dc:date
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Salih, Anmar Mahdi
Advisor dc:contributor.advisor
  • Goswami, Tarun

Subjects

dc:subject × 18

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Salih, Anmar Mahdi. Biomechanical Simulation of Cardiovascular Implantable Electronic Device Leads with Residual Properties. doctoral thesis, Wright State University, 2024. http://rave.ohiolink.edu/etdc/view?acc_num=wright1714506706310622