Back to search

Oklahoma State University

Off-Axis Neutron Study From a Uniform Scanning Proton Beam Using Monte Carlo Code Fluka

Abstract

dc:description.abstract

The production of secondary neutrons is an undesirable byproduct of proton therapy. It is important to quantify the contribution from secondary neutrons to patient dose received outside the treatment volume. The purpose of this study is to investigate the off-axis dose equivalent from secondary neutrons using the Monte Carlo radiation transport code FLUKA. The study is done using a simplified version of the beam delivery system used at ProCure Proton Therapy Center, Oklahoma City, OK. In this study, a particular set of treatment parameters were set to study the dose equivalent outside the treatment volume inside a phantom and in air at various depths and angles with respect to the primary beam axis. Three different proton beams with maximum energies of 78 MeV, 162 MeV and 226 MeV and 4 cm modulation width, a 5 cm diameter brass aperture, and a small snout located 38 cm from isocenter were used for the study. The FLUKA calculated secondary neutron dose equivalent to absorbed proton dose, Hn/Dp, decreased with distance from beam isocenter. The Hn/Dp ranged from 0.11 ? 0.01 mSv/Gy for a 78 MeV proton beam to 111.01 ? 1.99 mSv/Gy for a 226 MeV proton beam. Overall, Hn/Dp was observed to be higher in air than in the phantom, indicating the predominance of external neutrons produced in the nozzle rather than inside the body.

Degree

thesis:*
Department dc:contributor.department
Physics
Grantor dc:publisher
Oklahoma State University
Year dc:date.issued
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Islam, Mohammad Rafiqul
Advisor dc:contributor.advisor
  • Benton, Eric R.
Committee members dc:contributor.committeemember
  • Yukihara, Eduardo G.
  • Polf, Jerimy C.

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • Open Access
  • Copyright is held by the author who has granted the Oklahoma State University Library the non-exclusive right to share this material in its institutional repository. Contact Digital Library Services at lib-dls@okstate.edu or 405-744-9161 for the permission policy on the use, reproduction or distribution of this material.
Language dc:language
en_US

Identifiers

dc:identifier.*
Mods Identifier Filename
Islam_okstate_0664M_12614.pdf

Chain of custody

source
Harvested from
Oklahoma State University
Base URL
openresearch.okstate.edu/server/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Islam, Mohammad Rafiqul. Off-Axis Neutron Study From a Uniform Scanning Proton Beam Using Monte Carlo Code Fluka. Oklahoma State University, 2013. https://hdl.handle.net/20.500.14446/11092