Abstract

dc:description.abstract

Moisture damage is one of the major issues causing premature failure of Hot Mix Asphalt (HMA) pavements. However, there are no reliable test methods to determine moisture sensitivity in the laboratory. Moisture Induced Sensitivity Tester (MIST) is a new procedure that replicates moisture conditioning in the laboratory. However, the MIST does not have a standard test method and current testing is performed based on the manufacturer recommended settings. A ruggedness study (ASTM E1169) was performed on the MIST to determine if the tolerances of the test parameters have any impact on test results. The study was performed on only one mix. The manufacturer suggested test conditions are pressure, temperature, air void content (VTM) and height of compacted sample. The effect of the tolerances of these test conditions on indirect tensile strength (ITS) and Volume Change of the MIST conditioned samples were analyzed. The results from this study show that the tolerances on VTM and height of the sample had an effect on ITS of the HMA compacted samples while the VTM alone had an impact on Volume Change. A small experiment was performed to determine if the tolerance of the water bath soak after MIST conditioning had an impact on ITS values of the compacted HMA samples. The results suggest that the recommended 2-3 hour water bath soak had an effect on ITS values.

Degree

thesis:*
Department dc:contributor.department
Civil & Environmental Engineering
Grantor dc:publisher
Oklahoma State University
Year dc:date.issued
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Kaukuntla, Preetham
Advisor dc:contributor.advisor
  • Cross, Stephen A.
Committee members dc:contributor.committeemember
  • Lewis, Michael Phil
  • Yang, Xiaoming

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • Open Access
  • Copyright is held by the author who has granted the Oklahoma State University Library the non-exclusive right to share this material in its institutional repository. Contact Digital Library Services at lib-dls@okstate.edu or 405-744-9161 for the permission policy on the use, reproduction or distribution of this material.
Language dc:language
en_US

Identifiers

dc:identifier.*
Mods Identifier Filename
Kaukuntla_okstate_0664M_13358.pdf

Chain of custody

source
Harvested from
Oklahoma State University
Base URL
openresearch.okstate.edu/server/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Kaukuntla, Preetham. Standard Ruggedness Study on Moisture Induced Sensitivity Tester. Oklahoma State University, 2014. https://hdl.handle.net/20.500.14446/14930