Back to search

Oklahoma State University

Analysis of the Lowest Natural Frequencies of Heat Exchanger Tubes

Abstract

dc:description.abstract

The objective of this thesis was to find the lowest three natural frequencies of heat exchanger U-tubes by numerical and experimental methods. The results were transformed into a usable form for a heat exchanger design engineer.

Degree

thesis:*
Department dc:contributor.department
Mechanical Engineering
Grantor dc:publisher
Oklahoma State University
Year dc:date.issued
1982

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Lester, William Terry
Advisor dc:contributor.advisor
  • Lowery, Richard L.
Committee members dc:contributor.committeemember
  • Moretti, Petter M.
  • Good, James Keith

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • Open Access
  • Copyright is held by the author who has granted the Oklahoma State University Library the non-exclusive right to share this material in its institutional repository. Contact Digital Library Services at lib-dls@okstate.edu or 405-744-9161 for the permission policy on the use, reproduction or distribution of this material.
Language dc:language
en_US

Identifiers

dc:identifier.*
Mods Identifier Filename
Thesis-1982-L642a.pdf

Chain of custody

source
Harvested from
Oklahoma State University
Base URL
openresearch.okstate.edu/server/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Lester, William Terry. Analysis of the Lowest Natural Frequencies of Heat Exchanger Tubes. Oklahoma State University, 1982. https://hdl.handle.net/20.500.14446/16571