Back to search

Oklahoma State University

Reliability of transcallosal conduction time measurements at the abductor pollicis brevis

Abstract

dc:description.abstract

Transcallosal conduction time (TCT) can be measured using transcranial magnetic stimulation (TMS) during a submaximal voluntary contraction of a target muscle. By evaluating the time it takes for a potential to move across the corpus callosum (CC), we hope to see changes during phenomena such as cross-education. In the present study, we stimulated the contralateral and ipsilateral primary motor cortices during a 20% maximum voluntary contraction (MVC) of the abductor pollicis brevis (APB) of both hands in apparently healthy adults (n = 10). The motor evoked potential onset latency (MEPOL) that was obtained with the contralateral M1 stimulation was subtracted from the ipsilateral silent period onset latency (iSPOL) that was obtained through ipsilateral stimulation of the M1, which results in an approximate TCT. This was calculated using measurements at the participants' dominant and non-dominant hands and repeated again after more than 48 hours. Reliability measures of between the two visits showed that these measures were not reliable between visits. With further clarification on the definition of silent period onset latency (SPOL), and improvements in manual measuring techniques, we hope that measuring TCT can be a more accessible way to evaluate changes in interhemispheric interactions.

Degree

thesis:*
Discipline thesis:degree_discipline
Health and Human Performance
Grantor
Oklahoma State University
Year dc:date.issued
2021

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Danielson, Tyler L.
Advisor dc:contributor.advisor
  • DeFreitas, Jason
Committee members dc:contributor.committeemember
  • Trevino, Micheal
  • Dawes, Jay
  • Jacobson, Bert

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • Open Access
  • Copyright is held by the author who has granted the Oklahoma State University Library the non-exclusive right to share this material in its institutional repository. Contact Digital Library Services at lib-dls@okstate.edu or 405-744-9161 for the permission policy on the use, reproduction or distribution of this material.
Language dc:language
en_US

Identifiers

dc:identifier.*
Mods Identifier Filename
Danielson_okstate_0664M_17519.pdf

Chain of custody

source
Harvested from
Oklahoma State University
Base URL
openresearch.okstate.edu/server/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Danielson, Tyler L.. Reliability of transcallosal conduction time measurements at the abductor pollicis brevis. Oklahoma State University, 2021. https://hdl.handle.net/20.500.14446/337103