The rapid increase in illicit manufacturing of fentanyl and deaths due to fentanyl overdoses within the past few years has led to concerns for the safety of individuals unknowingly encountering it. In order to develop safer methods of field detection of fentanyl, understanding and observing fentanyl headspace is important. This study was conducted to determine the best sampling height for detecting fentanyl in fentanyl headspace. The headspace was sampled using solid phase microextraction (SPME) fibers at about 1 cm, 4 cm, 7 cm, and 9 cm from the fentanyl source. The samples were analyzed through manual injection of the SPME fibers on a gas chromatography – mass spectrometer (GC-MS). The relative abundance of fentanyl, 4-anilino-N-phenethyl-piperidine (4-ANPP), N-phenethyl-4-piperidone (NPP), and N-phenylpropanamide (NPPA) on these samples was measured. No 4-ANPP was detected throughout this study. It was determined that sampling at a further distance from the fentanyl source increased the amount of fentanyl and NPP detected, while distance had little effect on NPPA abundance. It was also determined that an increase in humidity increased the amount of fentanyl and NPP detected within the range of 30-45% humidity.

Degree

thesis:*
Discipline thesis:degree_discipline
Forensic Science
Grantor
Oklahoma State University
Year dc:date.issued
2023

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Cothran, Gwendolyn Grace
Advisor dc:contributor.advisor
  • Wagner, Jarrad
Committee members dc:contributor.committeemember
  • Simon, Alison
  • Hess, James

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • Open Access
  • Copyright is held by the author who has granted the Oklahoma State University Library the non-exclusive right to share this material in its institutional repository. Contact Digital Library Services at lib-dls@okstate.edu or 405-744-9161 for the permission policy on the use, reproduction or distribution of this material.
Language dc:language
en_US

Identifiers

dc:identifier.*
Mods Identifier Filename
Cothran_okstate_0664M_18089.pdf

Chain of custody

source
Harvested from
Oklahoma State University
Base URL
openresearch.okstate.edu/server/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Cothran, Gwendolyn Grace. Characterization of fentanyl headspace using solid phase microextraction: Effects of sampling height and humidity at fixed volume and temperature. Oklahoma State University, 2023. https://hdl.handle.net/20.500.14446/338904