Back to search

Oklahoma State University

Performance evaluation of limited area sprinkler systems in large-scale burn experiments

Abstract

dc:description.abstract

Many existing high-rise buildings remain non-sprinklered and highly vulnerable to fires. The limited area sprinkler system is a partial sprinkler system which can be used as a retrofit to existing high-rise buildings based on NFPA 101 (2021), balancing cost and safety. It provides a practical, effective, and economical fire protection solution for existing buildings where a complete retrofit is challenging due to costs, structural constraints, or historical preservation concerns. This study investigated the performance of a limited area sprinkler system by two large-scale burn tests. It compared two dwelling unit protection approaches provided by NFPA 101 (2021), Section 31.3.5.6.2: a single sprinkler above the unit entry door versus a 20-minute fire-rated entry door. Temperatures and radiant heat flux were recorded, with tenability criteria defined by thresholds of 80 °C (176 °F) and 2.5 kW/m² at human head level. The limited area system maintained the corridor tenable in both burns. In terms of protecting the interior of the dwelling unit, the sprinkler strategy controlled the temperatures significantly lower than the fire door strategy at human head level. In conclusion, even partial sprinkler coverage markedly improved life safety by preserving egress tenability and limiting fire spread and damage. These findings underscore the life safety benefits of the limited area system, informing building code compliance and retrofit strategies.

Degree

thesis:*
Discipline thesis:degree_discipline
Engineering Technology
Grantor
Oklahoma State University
Year dc:date.issued
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Wang, Minghao
Advisor dc:contributor.advisor
  • Charter, Virginia R.
Committee members dc:contributor.committeemember
  • Hoskins, Bryan Lawrence
  • Park, Haejun

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • Open Access
  • Copyright is held by the author who has granted the Oklahoma State University Library the non-exclusive right to share this material in its institutional repository. Contact Digital Library Services at lib-dls@okstate.edu or 405-744-9161 for the permission policy on the use, reproduction or distribution of this material.
Language dc:language
en_US

Identifiers

dc:identifier.*
Mods Identifier Filename
WANG_okstate_0664M_19130.pdf

Chain of custody

source
Harvested from
Oklahoma State University
Base URL
openresearch.okstate.edu/server/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Wang, Minghao. Performance evaluation of limited area sprinkler systems in large-scale burn experiments. Oklahoma State University, 2025. https://hdl.handle.net/20.500.14446/346571