Back to search

Oklahoma State University

Investigations on trans-luminal photon diffusion in steady-state and frequency-domain

Abstract

dc:description.abstract

This work presents the study of photon diffusion in a homogenous medium bounded externally (known as "concave") or internally (known as "convex") by an infinitely long circular cylindrical applicator. Focusing initially on steady-state condition, the photon diffusion in these two geometries is solved in cylindrical coordinates. The analytic solutions and their approximations are evaluated numerically for two specific cases: (1) the detector is placed only azimuthally with respect to the source and (2) the detector is placed only longitudinally with respect to the source. The effect of the applicator's curvature and radius on the photon fluence rate in comparison to that in the semi-infinite geometry is demonstrated qualitatively. The developed analytics are then examined through three approaches: (a) finite-element-method (FEM), (b) Monte Carlo (MC) simulation, and (c) experimental measurement. Despite that these quantitative examinations have to be conducted for applicators with large length-to-radius ratio to approximate the infinite-length condition modeled in the analytics, the results obtained for two "concave" and three "convex" applicator dimensions validated the quantitative accuracy of the analytic treatments in the diffusion regime. This work further demonstrates analytically for large radius applicator and verifies numerically using FEM and MC methods for small radius applicator the phenomenon that on the tissue-applicator interface of either "concave" or "convex" geometry there exists a unique set of spiral-paths, along which the steady-state photon fluence rate decays at a rate equal to that along a straight-line in a planar semi-infinite geometry. It is also found that for the medium containing an anomaly that is aligned azimuthally with the spiral-paths and has either positive or negative contrast of absorption or scattering coefficient over the background medium, the photon fluence rate along the homogenous-medium associated spiral-paths is macroscopically indistinguishable from, and microscopically close to, that along a straight line in a semi-infinite geometry. The last chapter of this work provides the frequency-domain analysis of the photon diffusion in both "concave" and "convex" geometries. Employing the same methodology as that in the steady-state study, such physical quantities as the amplitude of AC photon fluence, the modulation depth and the phase are explicitly studied.

Degree

thesis:*
Discipline thesis:degree_discipline
Electrical Engineering Technology
Grantor
Oklahoma State University
Year dc:date.issued
2012

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Zhang, Anqi
Advisor dc:contributor.advisor
  • Piao, Daqing
Committee members dc:contributor.committeemember
  • Bunting, Charles F.
  • Zhang, Weili
  • Wu, Jiahong

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • Open Access
  • Copyright is held by the author who has granted the Oklahoma State University Library the non-exclusive right to share this material in its institutional repository. Contact Digital Library Services at lib-dls@okstate.edu or 405-744-9161 for the permission policy on the use, reproduction or distribution of this material.
Language dc:language
en_US

Identifiers

dc:identifier.*
Mods Identifier Filename
Zhang_okstate_0664D_12392

Chain of custody

source
Harvested from
Oklahoma State University
Base URL
openresearch.okstate.edu/server/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Zhang, Anqi. Investigations on trans-luminal photon diffusion in steady-state and frequency-domain. Oklahoma State University, 2012. https://hdl.handle.net/20.500.14446/7762