Back to search

Oklahoma State University

Evaluation of a Segmental Titanium Implant for Mandibular Reconstruction Using a Critical Size Defect Model in the Dog--A Pilot Study

Abstract

dc:description.abstract

Craniomaxillofacial trauma and tumor resection are common causes of large mandibular defects in human beings and animals. Restoration of function and occlusion via rigid fixation is the goal of reconstructive procedures for unstable fractures and segmental defects. The aims of this pilot study were to describe the use of a porous titanium alloy implant (Regenerex) in comparison to cortical strut allografting techniques in the repair of critical size defects (CSD) in the dog edentulous mandible and report upon the operative technique and complications encountered with the procedures and novel application of this porous titanium alloy. Ten purpose-bred, male and female adult mongrel dogs between 2 to 3 years of age, weighing 20-25 kg, and without evidence of craniomaxillofacial or systemic disease had left sided dental extractions extending from the mandibular canine tooth to the last molar. Once healed, a 40mm segmental ostectomy was performed and repaired with a 2.0 locking titanium reconstruction plate augmented with either an interfragmentary cortical strut allograft (n=5) or the Regenerex implant (n=5). Dogs were euthanized and mandibles harvested for gross evaluation and histopathology. Osteointegration occurred in the 3 month Regenerex implanted dog only. The cortical strut allograft implanted animals demonstrated new bone formation and incorporation of the allograft in all but 1 dog that experienced plate breakage. The use of a porous titanium alloy implant designed to facilitate osteointegration for canine mandibular reconstruction following creation of a critical size defect has not been previously reported. Osteointegration could not be demonstrated in patients beyond three months postoperatively. The authors suspect inadequate contouring of the implant to be responsible for the failure.

Degree

thesis:*
Department dc:contributor.department
Veterinary Pathobiology
College dc:contributor.school
Center for Veterinary Health Sciences
Grantor dc:publisher
Oklahoma State University
Year dc:date.issued
2009

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ricker, Zachary Hunter
Advisor dc:contributor.advisor
  • Bartels, Kenneth E.
Committee members dc:contributor.committeemember
  • Rochat, Mark
  • Breshears, Melanie

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • Open Access
  • Copyright is held by the author who has granted the Oklahoma State University Library the non-exclusive right to share this material in its institutional repository. Contact Digital Library Services at lib-dls@okstate.edu or 405-744-9161 for the permission policy on the use, reproduction or distribution of this material.
Language dc:language
en_US

Identifiers

dc:identifier.*
Mods Identifier Filename
Ricker_okstate_0664M_10251.pdf

Chain of custody

source
Harvested from
Oklahoma State University
Base URL
openresearch.okstate.edu/server/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Ricker, Zachary Hunter. Evaluation of a Segmental Titanium Implant for Mandibular Reconstruction Using a Critical Size Defect Model in the Dog--A Pilot Study. Oklahoma State University, 2009. https://hdl.handle.net/20.500.14446/9828