Back to search

Oklahoma State University

Measurements of Frost Growth on Louvered Folded Fins of Microchannel Heat Exchangers

Abstract

dc:description.abstract

Microhannel heat exchangers with louvered folded fins are subjected to frequent frost and defrost cycles when used in outdoor evaporator coils of air-source heat pump systems. Despite their potential for heat transfer enhancements, understanding the root causes that penalize microchannel heat exchangers during frosting operating conditions is still an open question. This thesis presents a new experimental methodology to study frost growth on louvered folded fins of microchannel heat exchangers. The paper demonstrates the feasibility of the frost mass and frost thickness measurements and, through a series of controlled laboratory experiments, provides new data of frost growth on louvered fins. Fin surface temperature was directly measured during actual frosting operating conditions and relations with heat transfer rates, air-side pressure drops, and frosting cycle times are discussed. The experimental results suggested that the frost mass increased linearly with time and water vapor did not experience any measurable time delay before it began to frost and to accumulate on the fins. The air-side flow blockage due to frost accumulation on the front leading edge of the fins was strongly dependent on the fin surface temperature and the data confirmed that the flow blockage was the key factor for the heat transfer capacity degradation during frosting operation.

Degree

thesis:*
Department dc:contributor.department
Mechanical & Aerospace Engineering
College dc:contributor.school
Engineering, Architecture, and Technology
Grantor dc:publisher
Oklahoma State University
Year dc:date.issued
2011

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hong, Tommy
Advisor dc:contributor.advisor
  • Cremaschi, Lorenzo
Committee members dc:contributor.committeemember
  • Fisher, Daniel E.
  • Lilley, David G.

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • Open Access
  • Copyright is held by the author who has granted the Oklahoma State University Library the non-exclusive right to share this material in its institutional repository. Contact Digital Library Services at lib-dls@okstate.edu or 405-744-9161 for the permission policy on the use, reproduction or distribution of this material.
Language dc:language
en_US

Identifiers

dc:identifier.*
Mods Identifier Filename
Hong_okstate_0664M_11883.pdf

Chain of custody

source
Harvested from
Oklahoma State University
Base URL
openresearch.okstate.edu/server/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Hong, Tommy. Measurements of Frost Growth on Louvered Folded Fins of Microchannel Heat Exchangers. Oklahoma State University, 2011. https://hdl.handle.net/20.500.14446/9946