Back to search

Universität Oldenburg

Speech recognition tested at fixed, positive signal-to-noise ratios using time compression: Methods and applications

Abstract

dc:description.abstract

In daily communication the signal-to-noise ratio (SNR) of speech and background noise is usually positive. To evaluate the performance of hearing aids in such situations, a speech-in-noise test was introduced that presents time-compressed speech at fixed positive SNRs. Based on the Oldenburg sentence test, speech recognition thresholds were determined as a function of SNR and of the speech rate. A uniform and a non-uniform time compression algorithm were tested. Subjective and objective analysis indicated advantages of the uniform algorithm. Learning effects of the time-compressed and the original speech test were compared. A test procedure using adaptive speech rate was optimized for effective recognition measurements. Evaluating two single-microphone noise reduction algorithms showed the potential of the method for discriminating across these hearing aid algorithms at positive SNRs. The method can extend tests of speech in noise and of hearing aid benefit to a range of positive SNRs.

Degree

thesis:*
Level dc:type.qualificationlevel
phd
Grantor dc:publisher.institution
Universität Oldenburg
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Schlüter, Anne
Advisor dc:contributor.advisor
  • ARRAY(0x55b969baaf50)

Subjects

dc:subject × 1

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
http://oops.uni-oldenburg.de/2758/

Chain of custody

source
Harvested from
Carl von Ossietzky Universität Oldenburg
Base URL
oops.uni-oldenburg.de/cgi/oai2
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Schlüter, Anne. Speech recognition tested at fixed, positive signal-to-noise ratios using time compression: Methods and applications. phd thesis, Universität Oldenburg, 2016. http://oops.uni-oldenburg.de/2758/