Carl von Ossietzky Universität Oldenburg
Development and Clinical Validation of the Indonesian Matrix Sentence Test
Abstract
dc:description.abstractObject: The aim of this thesis was the development of the Indonesian matrix sentence test INDMatrix for speech intelligibility measurements in noise and the clinical validation with hearing-impaired (HI) patients. Study design: The test development followed the international standard procedure, and included recordings, cutting of the sound files, optimization of the speech material and evaluation measurements. Firstly, a 50-word base matrix consisting of 10 names, 10 verbs, 10 numerals, 10 nouns and 10 adjectives was established and recorded with a female native Indonesian speaker. In the optimization measurements, the speech reception thresholds (SRT) of 50% intelligibility and the slopes (S50) of the word-specific speech recognition functions were obtained for each word realization. By applying level corrections, the speech material was homogenized in speech intelligibility. The evaluation measurements aimed at the establishment of normative data for normal-hearing (NH) listeners, the assessment of the training effect and the verification of test list equivalence. In cooperation with clinical partners in Indonesia, the INDMatrix test was validated for its application in clinical population. Study sample: Twenty three NH listeners participated in the optimization measurements conducted in Oldenburg. The evaluation and validation measurements were a multicenter study involving 3 measurement sites (Oldenburg, Bandung, and Jakarta). Total of 25 NH listeners participated in the evaluation measurement in Oldenburg and Bandung, and 23 HI listeners in the validation measurement in Bandung and Jakarta. Results: At the optimization stage, the word realization level was adjusted to the average word-specific SRT (-8.6 dB SNR) with maximum adaptation of ± 3 dB. Due to the level correction, the standard deviation (SD) of the test-specific SRT decreased from 2.2 dB to 0.6 dB. In that way, the homogeneity of speech items in intelligibility was improved. The SRT reference value for the NH-listeners measured adaptively in noise resulted in -8.2 ± 0.8 dB SNR (SD across listeners). At least 2 training lists of 20 sentences are necessary before starting the real measurement to avoid the training effect. The average of the test-specific SRT and slope across test lists was -9.1 dB (SD: 0.1 dB) and 14.5%/dB (SD: 1.0%/dB). The INDMatrix shows a high test sensitivity of 91.3%. Conclusion: The final version of the INDMatrix test with 20 test lists of 10 sentences has been successfully established and fulfills the international standards. The results are comparable to those of matrix tests established for other languages.
Degree
thesis:*- Level dc:type.qualificationlevel
- masters
- Grantor dc:publisher.institution
- Carl von Ossietzky Universität Oldenburg
- Year dc:date.issued
- 2021
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Primadita, Felicia
- Advisor dc:contributor.advisor
-
- ARRAY(0x55b969ba9770)
Subjects
dc:subject × 2Identifiers
dc:identifier.*- Repository record dc:identifier.uri
- http://oops.uni-oldenburg.de/4973/