Pohang University of Science and Technology
Molecular Imaging System Using Biocompatible Quantum Dot Probes
Abstract
Quantum dots (QDs) have proven the potential for imaging contrast agents by the bright luminescence, the resistance against photobleaching, and the multiplexing capability. For the application of a targeted image contrast agent, hyaluronic acid-quantum dot conjugates (HA-QDs) were synthesized via a simple and novel electrostatic coupling method. The conjugates were colloidally stable and size-tunable from 50 to 120 nm. The HA-QDs showed specific binding to cancer cells expressing HA receptor, LYVE-1, which suggests diagnostic and imaging applications. Through the comprehensive investigations on cytotoxicities, the HA-QDs showed remarkably low cytotoxicity, which suites them well for in vivo applications. Using the HA-QDs in small animal model, lymphatic vessels were visualized real-time in vivo for days. The HA-QDs showcase the potentials toward real-time visualization of changes in lymphatic vessels such as lymphangiogenesis. Near-infrared (NIR) QDs can promise a new modality for in vivo bio-imaging and future medical imaging applications. To verify the capability for the clinical imaging applications, QD imaging capabilities were compared in the first optical window (FOW) at 700-900 nm using QDs that emit at around 800 nm (800QDs) and the second optical window (SOW) at 1000-1400 nm using QDs that emit at around 1300 nm (1300QDs), respectively. QD imaging depths in biological tissues such as bovine liver and porcine skin were investigated using the criteria of contrast-to-noise ratio and relative apparent size. Due to the reduced scattering in SOW, the imaging depth in skin can be extended by ~3 times for 1300QD/SOW when compared with 800QD/FOW. In liver tissue, although 1300QD/SOW imaging and 800QD/FOW imaging showed similar imaging depths, the imaging depth of 1300QD/SOW imaging could be extended with longer excitation wavelengths by reducing the absorption of the illuminating photons. Effects of quantum yield (QY), concentration, incidence angle, polarization and fluence rate on imaging depth were quantified, and results were used to estimate imaging depths by 1300QD/SOW under hypothetical conditions. Under optimal conditions using continuous excitation at the FDA approved fluence rate, 1300QDs with 50 % QY may reach imaging depths of 29.7 mm in liver and 17.5 mm in skin tissue. To validate the estimates, imaging capabilities of QDs were compared using in vivo whole-body imaging of mice. Time-gated excitations with high fluence rate, software optimization of QD imaging, and advances in sensitivity of cameras in SOW are expected to further increase the imaging capability of QDs in SOW. For the in vivo imaging application of NIR QDs, an in vivo real-time multiplexed imaging system was developed. It has a Si CCD and an InGaAs CCD which in combination cover the NIR wavelength range from 700 to 1700 nm. Each CCD has a filter wheel with emission filters which enable the real-time multiplexed imaging of relatively slow events. To verify the multiplexed NIR imaging system, two QD solutions with different emission wavelengths were simultaneously observed in both in vitro and in vivo using small animal model. NIR QDs with different emission wavelengths can be selectively imaged by various emission filters. Each NIR emission can be converted by pseudo colors and merged with visible color image to generate multiplexed imaging. This suggests that two or more biological processes and their interactions can be longitudinally visualized in a live animal model through the multiplexed imaging system.
Author and committee
dc:creator, dc:contributor.*- Author
-
- 원나연
Identifiers
dc:identifier.*- Identifier
- hdl:2014.oak/1418
- Mods Identifier Other
- OAK-2014-00916