Abstract
Simultaneous removal of the three major air pollutants such as CO, HC and NOx emitted from gasoline engines using a three-way catalyst (TWC) converter is a well-established, commercially proven aftertreatment technology. The TWC contains noble metals such as rhodium (Rh), palladium (Pd) and/or platinum (Pt) as active catalytic ingredients for TWC reactions. In addition, a variety of promoters and stabilizers are also included in the modern TWC system to improve the catalyst activity and stability. However, the TWC is prone to deactivation due to the thermal degradation of catalyst components and chemical poisoning by various contaminants present in the exhaust stream. Current and upcoming emission standards such as ULEV and SULEV require not only a high catalytic performance but also catalyst durability up to 120,000 miles. Thus, it is important to develop a thermally and chemically durable TWC through better understanding of the catalyst deactivation mechanism. In the present study, the deactivation of TWCs in the warm-up catalytic converters (WCC) installed in a passenger vehicle has been investigated with respect to the catalyst field-mileages. Three test modes have been employed to examine the alteration of the TWC performance upon aging