Novel Implant Concepts for the Reconstruction of the Sound-Conduction Apparatus
Abstract
dc:description.abstractHypotheses The present work broaches the issues of the reconstruction of biomimicking functions of TM and the ossicular chain replacements, more specific, the total reconstructions of the both. The following hypotheses have been proposed: i. The structure and acousto-mechanical function of the TM can be reconstructed using biomaterials and additive biofabrication techniques. In particular, the biomaterials for the TM involve the use of polycaprolactone (PCL) in connection with the additive method of melt electrowriting (MEW) for developing a novel TM graft. ii. By implementing a joint in a rigid titanium total ossicular replacement prosthesis (TORP) sound transmission from the tympanic membrane to the stapes footplate can be restored, especially in case of superimposed positive and negative quasi-static pressure. The joint for the total prosthesis consists of a ball-and-socket friction joint and a silicone coating, which is inserted in the titanium shaft. Material and Methods The investigations of the function of the replacements for the ossicular chain and the tympanic membrane were performed by measuring the vibration velocities of the specific structures with a laser Doppler vibrometer (LDV) to calculate the individual sound transfer functions. For each measurement, a multi sinusoidal signal in the range of 100 Hz to 5000 Hz was used as sound pressure excitation in the auditory canal. Ossicular chain reconstruction: Experimental measurements were performed on nine fresh cadaveric human temporal bones. Five were used for the comparison between the rigid titanium TORP, as the current standard, and the flexible silicone coated ball and socket joint TORP. The middle ear transfer function (METF) was measured for the intact ossicular chain at normal pressure and at ambient pressure of 2.5 kPa, both positive and negative pressure. The pressure was applied in the ear canal, after the specific tympanoplasty reconstructions. Tympanic membrane reconstruction: Scaffolds and tympanic membranes were measured in a self-build test stand for a direct comparison of their vibration behavior. The scaffold batches consisted of different structural parameter settings: Four, six and eight fiber layers, a layer-to-layer offset of 90° and 45° to the adjacent layers, fiber spacing of 150 µm and 250 µm and a fiber thickness of 10 µm and 15 µm. A fiber diameter of 15 µm was only provided for 150 µm fiber spacing, because it was assumed, that the vibration behavior relations between the different parameters are equivalent. The sample size for each combination was n=5 for each batch. For regarding influences in positioning and clamping, each scaffold was measured three times, with a rotation at repositioning of the scaffold between the measurements of about 30 degrees. Collagen was applied to the scaffold with 4 layers, a 45° rotation between layers, 10 µm fiber diameter and 250 µm fiber spacing, which seemed to be one most suitable for mimicking the TM vibration. Four human TM were investigated with one measurement in the test stand under the same clamping force. Results Ossicular chain reconstruction: The additional flexible joint improved the PTA (Pure Tone average (PTA) frequencies 500 Hz, 1000 Hz, 2000 Hz and 4000 Hz) by approximately 1.2 dB compared to the rigid TORP at initial reconstruction and by 0.7 dB after three pressure cycles. The intact ossicular chain showed PTAs of -9.8 (SD 2.8) dB for a positive pressure of 2.5 kPa in the tympanic cavity and -9.4 (SD 3.5) for a negative pressure of -2.5 kPa in the tympanic cavity. The reconstruction with flexible TORP showed a PSA of -18.7 (SD 8.6) dB for 2.5 kPa positive pressure and -7.9 (SD 2.6) dB for -2.5 kPa negative pressure in the tympanic cavity. The reconstruction with rigid TORP showed a PSA of -12.4 (SD 3.4) dB for 2.5 kPa positive pressure and -19.3 (SD 4.8) dB for -2.5 kPa negative pressure in the tympanic cavity. Due to the resulting deterioration in contact with the prosthesis foot, this led to a comparatively greater decrease in the PTA, especially for the flexible TORP. Since the flexible TORP was implanted with pre-tensioning, the decrease in PTA with negative pressure in the tympanic cavity was significantly lower than with the rigid TORP, which can be attributed to the compensation of the change in length by the movable prosthesis head. Tympanic membrane reconstruction: Depending on the layer size and fiber thickness, together with a higher magnitude of about 15 to 20 dB (ref 1 µm/Pa), the various scaffold designs showed similar or different first resonance frequency (fiRF), in comparison to the human TMs. The scaffolds with four fiber layers provided the best comparable fiRFs, being in the range of 150 Hz to 470 Hz. An implant with a higher magnitude of vibration is beneficial for inhibited sound transfer caused by stiffness increases like scar tissue induced tension during the healing process, as well as coupling to the ossicular chain or implants. Conclusion In terms of sound transfer, it is possible to design biomimicking replacements of the ossicular chain and the tympanic membrane with current materials and fabrication methods. The sound transmission behavior of a flexible TORP and the vibration behavior of PCL TM scaffolds are close to their natural counterparts, the ossicular chain and the TM, respectively.
Degree
thesis:*- Level thesis:degree_level
- thesis.doctoral
- Department thesis:degree_department
- Medizinischen Fakultät Carl Gustav Carus
- Grantor dc:publisher
- Technische Universität Dresden
- Year dc:date.issued
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Stoppe, Thomas
Subjects
dc:subject × 18Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- free
- info:eu-repo/semantics/openAccess
- Language dc:language.dcterms_iso639_2
- eng
Identifiers
dc:identifier.*- Dc Publisher Identifier
- 2024114-8