Back to search

Technische Universität Dresden

Macroscopic and microscopic properties of thermoplastic polyurethane magnetorheological elastomers

Abstract

dc:description.abstract

The work aimed at characterising both mechanical and microstructural properties of thermo-sensitive magnetorheological elastomers under simultaneous stimulation by magnetic field and temperature. This was realised by the in-house developed test setups and specific investigation methods so that the stimulation conditions remain the same during both the macro- and microscopic investigations. Thermoplastic polyurethane elastomer was used as matrix material due to their superior mechanical properties, wide range of application potential and recyclability. Due to the use of micron-sized iron particles, achieving a homogeneous distribution in the matrix was met with sedimentation issues. Precise sample preparation methods overcame the sedimentation issues and were further optimised to achieve reproducible isotropic TPU-MRE samples. Rod-shaped samples were tested for mechanical and microstructural properties using in-house developed test setups adapted for a commercial rheometer and in-house laboratory micro-CT system. Mechanical properties like Young’s modulus and shear modulus were investigated by conducting quasi-static tensile and torsion tests, respectively. Shear storage and loss moduli were determined by conducting frequency sweep dynamic oscillation tests. The tests were conducted at three different temperatures, without and with magnetic field. The developed test setups were equipped to stimulate the samples with similar stimulating conditions. Thereby enabling the correlation of mechanical and microstructural properties of the samples. The test setups were validated with standard instruments, and the deviations in results were found to be within 4%. The samples were tested for mechanical properties within their linear viscoelastic regime. To begin with, an optimal sample composition was determined by testing the samples with different ratios of constituent components of the elastomer matrix. The elastomer samples were first tested for their thermal properties and later with iron particles for their magnetorheological properties. The TPU elastomer samples without plasticizer showed a greater decrease in moduli with the increase in temperature. The dynamic oscillation tests revealed their strain-dependent property. Whereas among the TPU-MRE samples, the MR effect was higher among the ones with plasticizers under all test and stimulation conditions. These results allowed to conduct further investigations on the TPU-MRE sample with plasticizer and lower hardener content. TPU-MRE samples were further tested for the influence of particle content on the MR effect. The samples were tested with 40, 50, and 60 Wt.% of iron particles. Microstructural investigations were conducted at two different temperatures without and with magnetic stimulation. Four series of tomographic measurements were performed with different sequences of stimulation. The first series is stimulation by only the magnetic field, the second by only temperature, third and fourth by both magnetic field and temperature with different orders of stimulation. Such a measurement methodology will provide clear information about the influence of each stimulating parameter individually and in combination causing the microstructural changes. Detailed geometrical information of individual particles from each tomogram is obtained by employing well-established digital image processing methods. The statistical data on the initial state of the sample further proved the selected particle size and shape distribution and their homogeneous discribution in the matrix. Microstructural investigations were conducted on two levels, one on an individual particle basis by particle tracking method and the other on the particle structure in the sample as a whole by using the Pair Correlation Function. Tracking of individual particles from one tomogram data to the adjacent within a series is performed using the particle’s positional and geometric information. The tracked particles provided insights into the translation behaviour of the particles in the sample subjected to the specific stimulation. The information of particle motion as global particle structure is investigated from PCF. The stimulation of the sample has resulted in a recognisable distortion in the PCF maxima along the axial direction of the sample. This is mainly due to the thermal expansion and the applied magnetic field along the cylindrical axis of the sample.

Degree

thesis:*
Level thesis:degree_level
thesis.doctoral
Department thesis:degree_department
Faculty of Mechanical Science and Engineering
Grantor dc:publisher
Technische Universität Dresden
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Kare Gowda, Darshan
Advisor dc:contributor.advisor
  • Odenbach, Stefan

Subjects

dc:subject × 7

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • free
  • info:eu-repo/semantics/openAccess
Language dc:language.dcterms_iso639_2
eng

Identifiers

dc:identifier.*
Dc Publisher Identifier
2024114-8
Ddb Identifier Erstkat Id
1973322145

Chain of custody

source
Harvested from
QUCOSA
Base URL
www.qucosa.de/oai/
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Kare Gowda, Darshan. Macroscopic and microscopic properties of thermoplastic polyurethane magnetorheological elastomers. thesis.doctoral thesis, Technische Universität Dresden, 2026. https://nbn-resolving.org/urn:nbn:de:bsz:14-qucosa2-1035792