Back to search

Technische Universität Dresden

The Development of a Passive High Performance Cryogenic Fiber Optic Gyroscope

Abstract

dc:description.abstract

This thesis explores the engineering challenges of envisioning and realizing a cryogenic fiber optic gyroscope and conducting further amplified frame dragging effect experiments. Due to limited resources, the gyroscope had to employ an unconventional configuration, the so called 3x3-configuration using a 3x3-fiber optic coupler. Together with the strict performance re-1quirements, the work resulted in a 3x3-configuration Fiber Optic Gyroscope (3x3-FOG) that substantially outclasses all previous similar devices, and potentially provides the most resource-effective option to achieve a certain gyroscope performance window. Hence, from basic research emerged a technology with useful real-world upside compared to the state-of-the-art. This gyroscope is also the first ever gyroscope that has been verified to, with a single setup, measure rotation with its sensing apparatus at cryogenic temperatures or at room temperature. This achievement has more academic value but is nonetheless a novelty. The development provides new insights about optical fibers at cryogenic temperatures in general, which is frequently used for sensing applications. The thesis lays the technical groundwork for further amplified frame dragging experiments, but regrettably contains no final declaration on existence or non-existence of the effect, as the experiment setup faced multiple hardships. Firstly, a literature research chapter describes all the fundamentals on gyroscopes, FOG, optical fiber, and frame dragging that are required for a profound understanding of the subsequent content. The next chapter discusses the envisioned 3x3-FOG in depth, describing the decision making process, all technical details of the design and the analysis, and finally the achieved performance at room temperature, and at cryogenic temperatures. Potential future research and further improvements are thoroughly discussed. The final chapter concerns itself with the amplified frame dragging experiment. The mechanical and electrical design of the setup is described in detail, followed by the results of initial measurements. Finally, a path to a conclusive meaningful amplified frame dragging experiment is outlined.

Degree

thesis:*
Level thesis:degree_level
thesis.doctoral
Department thesis:degree_department
Maschinenwesen
Grantor dc:publisher
Technische Universität Dresden
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Windeck, Frank Kersten Ulrich

Subjects

dc:subject × 8

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • free
  • info:eu-repo/semantics/openAccess
Language dc:language.dcterms_iso639_2
eng

Identifiers

dc:identifier.*
Dc Publisher Identifier
2024114-8
Ddb Identifier Erstkat Id
197316194X

Chain of custody

source
Harvested from
QUCOSA
Base URL
www.qucosa.de/oai/
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Windeck, Frank Kersten Ulrich. The Development of a Passive High Performance Cryogenic Fiber Optic Gyroscope. thesis.doctoral thesis, Technische Universität Dresden, 2026. https://nbn-resolving.org/urn:nbn:de:bsz:14-qucosa2-1043188