Technische Universität Dresden
Analysis of volatile organic compounds from food contact materials: paperboard and fluoropolymer-coatings
Abstract
dc:description.abstractPaper and board are used for packaging of moist as well as dry food and might therefore be exposed to a variety of relative humidity (rH) levels. For testing the transfer of off-flavours (taint) from packaging to food via gas phase (DIN EN 1230-2), rH has to be adjusted to 53 % or 75 %. In contrast, rH is neither taken into account when testing the odour (DIN EN 1230-1), nor in chemical migration of volatile organic substances (VOC) onto the adsorbent Tenax® (DIN EN 14338). The aim was to investigate the influence of relative humidity on the migration of VOC from recycled paper to Tenax® and the sensory profile of this material. Raising humidity caused an increase in the odour intensity as well as a change in the odour profile in human sensory tests. Likewise, gas chromatography-mass spectrometry (GC-MS) peak areas increased exponentially with humidity along with the number of detected substances. The strongest effect was observed at 75 and 100 % rH. Polar substances were more influenced by increasing humidity than less polar substances. The odour profile of the paper at 33 and 58% rH was described as cardboard-like, sweet and smoky. Impact substances for these olfactory impressions were (E)-2-nonenal, vanillin and 2-methoxyphenol as identified by GC-olfactometry (GC-O) and GC-MS. The increase of rH to 75 and 100 % resulted in the additional perception of cheesy/sweaty and fatty/rancid impressions, mainly caused by short-chain fatty acids and di-unsaturated aldehydes. Based on these results, rH has a strong effect on the desorption of VOC from paper and thus should be set to a defined level when testing the odour and the migration from paper and board according to DIN EN 1230-1 and DIN EN 14338, respectively. Fluoropolymer-coatings for kitchenware, like baking trays and frying pans, are made of polymeric per- and polyfluoroalkyl substances (PFAS) like polytetrafluoroethylene (PTFE), which is also known under the trade name Teflon. Non-polymeric PFAS are used as production aids in the fabrication of fluoropolymers. Growing concerns related to the impact of PFAS on the environment and the human health lead to an increasing interest in monitoring PFAS levels in food contact materials (FCMs) as well as their migration into food. The aim was to determine PFAS from fluoropolymer-based cookware coatings after thermal extraction by thermal desorption (TD)-GC-MS. MS measurements was performed using electron impact ionisation (EI) as well as positive and negative chemical ionisation (PCI and NCI). Injecting perfluorocarboxylic acids (PFCAs) and per- and polyfluoroethercarboxylic acids (PFECAs) into TD-GC-MS resulted in the detection of thermal degradation products: perfluoroalkenes and hydrides were formed due to CO2 and additional HF elimination, respectively. Beyond targeted analysis, a screening for PFAS was possible using group-specific fragments. Typical EI fragments were m/z 131 (CF2CFCF2+) for perfluoroalkenes, m/z 95 ([CF2(CH2)2OH]+) for fluorotelomer alcohols (FTOHs), and m/z 69 (CF3+) for nearly all PFAS. Typical fragments for hydrides were m/z 51 (CF2H+) and m/z 101 (CF3CFH+). Thermal extraction was done at 250 °C in a TD oven. Twenty cookware samples including baking trays, frying pans, baking mats and lab-made coating strips were investigated. No PFAS were detected in twelve samples (limits of detection (LODs): 1-13 ng/dm2). PFCAs (chain length: C5, C14-C23) were determined in a baking tray in individual amounts of up to 34 ng/dm2 (total 197 ng/dm2) and perfluorooctanoic acid (PFOA) in a baking mat at 3 ng/dm2 (all PFCAs measured as their degradation products: perfluoroalkenes). FTOHs were not detected in the samples. The PFECA perfluoro-2,5-dimethyl-3,6-dioxaheptanoic acid was quantified at 554 ng/dm2 in one coating intended for use in frying pans. Hydrides of the PFECA mixture Krytox were found in five baking trays in amounts of up to 2697 ng/dm2. None of the targeted PFAS were detectable in the five investigated frying pans. During screening for other VOC in the emissions of coatings, 175 compounds were identified including alkanes, alkenes, aromatic substances, esters, aldehydes, ketones, ethers, alcohols, carboxylic acids, siloxanes and sulphur-, nitrogen-, as well as chlorine-containing compounds (< 10 µg/dm2). The identified substances couldn’t be directly linked to the basic coating polymer of the kitchenware articles, which were PTFE and polyether sulfone (PES). All samples were subjected to a threefold thermal extraction. During the second and third consecutive extraction, no substances were above the LOD, concluding that a removal and no new formation of the investigated PFAS as well as the further VOC at 250 °C has occurred. Based on current knowledge, this is the first work presenting GC-MS measurements of several PFECAs and determining PFECAs in cookware articles. TD-GC-MS enables the detection of various volatile PFAS and PFAS degradation products as well as the performance of non-target analysis, which makes it a powerful method for emission testing.
Degree
thesis:*- Level thesis:degree_level
- thesis.doctoral
- Department thesis:degree_department
- Chemie und Lebensmittelchemie
- Grantor dc:publisher
- Technische Universität Dresden
- Year dc:date.issued
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Wolf, Nancy
Subjects
dc:subject × 9Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- free
- info:eu-repo/semantics/openAccess
- Language dc:language.dcterms_iso639_2
- eng
Identifiers
dc:identifier.*- Dc Publisher Identifier
- 2024114-8
- Ddb Identifier Erstkat Id
- 1981206485