Back to search

Universität Leipzig

Electrical and Structural Response of Graphite-Based Ion Detectors Under Controlled Ion Implantation

Abstract

dc:description.abstract

Deterministic creation of point defects by ion implantation supports a wide range of quantum and nanoelectronic technologies, including spin-based qubits such as NV centers in diamond and optically active defects such as G centers in silicon. A key challenge is the reliable detection of individual, low-energy ions at or near room temperature while keeping the detector concept simple to fabricate and scalable to dense arrays. This thesis addresses that challenge with nanometer-thin graphite used as a solid-state sensor. Ion impacts create defects that change the in-plane electrical resistance, which allows time-resolved detection of ion arrivals. The work develops a physical description that links defect creation and evolution to charge transport, implements low-noise electrical measurements that resolve discrete steps during irradiation, and demonstrates a device and readout approach that can be extended to large arrays. The intrinsic transport properties of graphite imply that restricting the conductive path to nanometer-scale widths significantly enhances the influence of an individual scattering center on the overall resistance. Consequently, optimized device geometry and low-noise electrical measurement techniques can extend the detection sensitivity toward the single-ion limit at room temperature. The combined experimental and theoretical approach reveals the coupling between defect generation and charge transport in graphite and establishes a quantitative framework for both optimizing single-ion detection and enabling precision defect engineering for emerging quantum technologies. Complementary Raman spectroscopy confirmed defect formation and structural modification of the graphite lattice, although the in-situ electrical measurements proved significantly more sensitive to the early stages of defect creation. The most important findings of this work are summarized in the following: -) Nanometer-thin graphite samples were irradiated with 5 keV beams of 14N2 +, 20Ne+, 40Ar+ and 84Kr+. In-situ electrical measurements reveal discrete, step-like increase in resistance coincident with ion impacts, followed by slow relaxations attributable to defect migration and recombination. -) Resistance changes corresponding to only a few hundred ion impacts were clearly resolved, establishing a detection limit within one order of magnitude of singe-ion sensitivity at room temperature. -) A method is developed to pattern graphite into nanometer-wide and micrometer long conduction paths using focused ion beam technique and reactive ion etching . It is shown, that graphite detectors with confined widths in the order of 50nm show resistance changes of about 2% per single-ion impact. -) A custom-build nanovoltmeter and synchronized were implemented to eliminate thermal and contact offset voltages during ion irradiation, allowing clear discrimination of ion-induced steps from electrical noise. -) Two complementary theoretical models were established. A semi-classical transport model combining SRIM-simulated defect spacing with fitted carrier densities, reproducing the resistance evolution over wide fluence ranges. A nucleation-and-growth based model, adapted from the Johnson-Mehl-Avrami formalism, that relates the progression of defects and defect clusters to the measured resistance, yielding physical meaningful Avrami exponents and effective damage cross-sections. -) From the introduced models and calculated defect volumes a conservative lower bound for the electron mean-free path of about 300nm at room temperature is derived, in agreement with literature values. -) Raman spectroscopy provides an independent confirmation of irradiation-induced defects. The appearance and growth of the D band, the evolution of the D to G intensity ratio, and changes in the 2D band line-shape confirm structural modification of the graphite lattice. While Raman tracks the cumulative damage, the in-situ electrical measurements are more sensitive during the earliest stages of defect creation. -) The detector concept and introduced fabrication processes can be scaled to multisensor arrays. Along with the demonstrated sensitivity and stability make this approach suitable for deterministic ion implantation and precise defect placement for potential applications in quantum devices.

Degree

thesis:*
Level thesis:degree_level
thesis.doctoral
Grantor dc:publisher
Universität Leipzig
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Küpper, Johannes Lukas

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • info:eu-repo/semantics/openAccess
Language dc:language.dcterms_iso639_2
eng

Identifiers

dc:identifier.*
URN
urn:nbn:de:bsz:15-qucosa2-1069296

Chain of custody

source
Harvested from
QUCOSA
Base URL
www.qucosa.de/oai/
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Küpper, Johannes Lukas. Electrical and Structural Response of Graphite-Based Ion Detectors Under Controlled Ion Implantation. thesis.doctoral thesis, Universität Leipzig, 2026.