Back to search

Technische Universität Dresden

Contrast Mechanisms for MRI-based Proton Beam Visualisation

Abstract

dc:description.abstract

The dosimetric potential of proton therapy is not yet fully exploited because of uncertainties mainly related to the present inability to routinely localise the deposited dose during treatment. MR-integrated proton therapy is currently being developed to provide real-time image guided treatment, which is expected to reduce this uncertainty by enabling the monitoring of organ motion as well as the detection of anatomical deviations from the planned scenario. In addition to this core task of in-beam MRI, its capability for the MRI magnitude signal-based visualisation of the proton beam during dose delivery was assessed once a first prototype in-beam MRI scanner was available and the feasibility of beam visualisation demonstrated. However, the radiation dose required to obtain beam visualisation images considerably exceeded clinical dose levels and successful beam visualisation was restricted to liquid- filled phantoms. Moreover, the irradiation-induced effects underlying the observed MRI magnitude signal changes as well as the associated MRI contrast mechanisms remained largely unexplained. Based on the versatile sensitivity of MRI to a variety of physico-chemical material changes inducible by proton beam irradiation, this imaging modality can be hypothesised to be capable of visualising the proton beam by a range of different contrast mechanisms. Consequently, to explain the preceding experimental results, to enable the MRI-based visualisation of the proton beam at lower dose levels than initially required and to assess the method’s eligibility for clinical use in phantom-based QA and in vivo dose verification, the MRI contrast mechanisms for proton beam visualisation required in-depth investigation. Therefore, a theoretical study based on a comprehensive literature research and back-of-the-envelope calculations was conducted as part of this work to identify possible contrast mechanisms for MRI-based proton beam visualisation. In parallel, phase imaging was developed at the in-beam MRI scanner to broaden the methodological spectrum available for the experimental study of the beam-induced MRI contrast mechanisms. Subsequently, complementing the preceding observational experimental phantom studies in MRI magnitude signal-based proton beam visualisation carried out at the Dresden proton therapy facility, an observational combined irradiation and imaging study in MRI phase signal-based proton beam visualisation was conducted. This experimental study served to assess whether proton irradiation also results in phase contrast, which expands the imaging methodology-based possibilities for sensitivity enhancement. Subsequently, comprehensive experimental phantom studies were designed supported by the results of the theoretical study of contrast mechanisms and conducted to identify the irradiation-induced effects and MRI contrast mechanisms underlying the MRI contrast detected in the observational studies. Moreover, possibilities for the further sensitisation of MRI to the irradiation-induced effects resulting in local image contrast were assessed and the methods’ applicability in tissue investigated. All experiments were conducted using two low-field in-beam MRI scanners at the fixed beam research beamline of the Dresden proton therapy facility. Among the MRI contrast mechanisms theoretically and experimentally investigated for MRI-based proton beam visualisation, irradiation-induced convection and oxygen depletion were found to cause the magnitude and phase difference contrast visible in the observational studies. While irradiation-induced convective flow in liquid phantoms was found to be exploitable at increased sensitivity using the phase signal-based method of VENC MRI, the irradiation-induced oxygen concentration changes in convection-restricted phantoms, which result in T1 relaxation time lengthening of water protons, were identified to be detectable at increased sensitivity using magnitude signal-based IR MRI methodology. Yet, even when using these more sensitive imaging methods, the dose levels required for the low-field MRI-based visualisation of the proton beam in the respective phantoms were still in the order of 10¹ Gy to 10² Gy. No image contrast could be generated in tissue-mimicking phantoms using the low-field MRI scanners. The application potential of convection-based proton beam visualisation in phantom- based QA of MR-integrated proton therapy is restricted because of its inherent flow dependence, which inevitably corrupts the geometrical dose distribution. Nevertheless, phase signal-based VENC imaging can already be applied for the qualitative verfication of phantom positioning relative to the deflected proton beam using radiation dose levels in the order of 10¹ Gy. Even though oxygen depletion-based proton beam visualisation may have the potential to yield geometrically and dosimetrically meaningful results in convection-restricted phantoms required for quantitative applications, it will have to compete with the similarly elaborate method of real-time MRI-evaluated gel dosimetry, which is already advanced in development on MR-linacs and proved adaptable to proton beam irradiation. Because of its questionable realisability in tissue and its presumably poor accuracy due to rapidly changing oxygenation levels in tumours, the clinical application potential of oxygen depletion imaging for in vivo beam verification can be considered low. In conclusion, the aims of this thesis have been achieved. Confirming selected hypothe- ses generated in this work, low-field in-beam MRI has been demonstrated to enable both the convection- and oxygen depletion-based visualisation of the proton beam in phantoms during dose delivery. Phase signal-based proton beam visualisation has been realised and applied for dose level sensitivity enhancement. The understanding of MRI-based proton beam visualisation and its boundary conditions has been greatly improved. The contrast mechanism-dependent application potential has been assessed and directions for future work have been identified. All in all, the results obtained in this work represent a strong foundation for future research targeted at the application of MRI-based proton beam visualisation.

Degree

thesis:*
Level thesis:degree_level
thesis.doctoral
Department thesis:degree_department
Medizinische Fakultät Carl Gustav Carus
Grantor dc:publisher
Technische Universität Dresden
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Schieferecke, Juliane

Subjects

dc:subject × 9

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • free
  • info:eu-repo/semantics/openAccess
Language dc:language.dcterms_iso639_2
eng

Identifiers

dc:identifier.*
Dc Publisher Identifier
2024114-8

Chain of custody

source
Harvested from
QUCOSA
Base URL
www.qucosa.de/oai/
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Schieferecke, Juliane. Contrast Mechanisms for MRI-based Proton Beam Visualisation. thesis.doctoral thesis, Technische Universität Dresden, 2026. https://nbn-resolving.org/urn:nbn:de:bsz:14-qucosa2-1069389