Back to search

Universität Leipzig

Macular pigment optical density measurements by one-wavelength reflection photometry – Influence of cataract surgery on the measurement results

Abstract

dc:description.abstract

Purpose: The main objective of the present study was the investigation of possible influence of lens opacification on macular pigment optical density (MPOD) measurements. Methods: 86 eyes of 64 patients (mean age 73.4(±8.3)years) were included in the study. MPOD was prospectively measured using one-wavelength reflection method (Visucam500, Carl Zeiss Meditec AG) before and after cataract extraction with implantation of a blue-light filtering intraocular lens (AlconSN60WF). The median of the maximum optical density (MaxOD) and the median of the mean optical density (MeanOD) measurements of macular pigment across the subject group were evaluated. Results: Statistically significant differences were noticed between pre-operative and post-operative measurements, the absolute values were generally lower after cataract extraction. The following median(lower/upper quartile) differences across the group were determined: MaxOD -33.8%(-46.2%/-19.1%), MeanOD -44.0%(-54.6%/-26.6%). Larger changes were observed in elderly patients (<70years of age: (n=25eyes) MaxOD -13.4%(-20.5%/3.6%), MeanOD -23.6%(-30.5%/-15.3%) versus patients ≥70years: (n=61eyes) MaxOD -40.5%(-53.2%/-30.1%), MeanOD -47.2%(-57.8%/-40.1%)) and in patients with progressed stage of cataract. MaxOD for lens opacification grade 1:(n=9eyes) -27.4%(-42.1%/-19.6%), 2:(n=26eyes) -35.0%(-44.2%/-25.3%), 3:(n=21eyes) -34.4%(-45.4%/-11.4%), 4:(n=25eyes) -32.6%(-53.2%/-6.4%) and 5:(n=5eyes) -53.5%(-61.7%/-38.7%) and MeanOD for cataract stage 1:(n=9eyes) -42.6%(-46.0%/-26.0%), 2:(n=26eyes) -44.1%(-51.8%/26.2%), 3:(n=21eyes) -45.7%(-54.7%/-24.7%), 4:(n=25eyes) -39.5%(-59.4%/-26.1%), 5:(n=5eyes) -57.0%(-66.1%/-51.4%). Conclusions: As established by comparison of pre- to post-operative measurements, cataract presented a strong effect on MPOD measured by one-wavelength reflection method. Particular care should therefore be taken when evaluating MPOD using this method in elderly patients with progressed stage of cataract. Future optimization of correcting parameters of scattered light and consideration of cataract influence may allow more precise evaluation of MPOD.

Degree

thesis:*
Level thesis:degree_level
thesis.doctoral
Department thesis:degree_department
Medizinische Fakultät
Grantor dc:publisher
Universität Leipzig
Year dc:date.issued
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Komar, Bogdana
Advisor dc:contributor.advisor
  • Dawczynski, Jens

Subjects

dc:subject × 10

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • free
  • info:eu-repo/semantics/openAccess
Language dc:language.dcterms_iso639_2
eng

Identifiers

dc:identifier.*
Persistent identifier dc:identifier.urn
https://nbn-resolving.org/urn:nbn:de:bsz:15-qucosa-172371

Chain of custody

source
Harvested from
QUCOSA
Base URL
www.qucosa.de/oai/
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Komar, Bogdana. Macular pigment optical density measurements by one-wavelength reflection photometry – Influence of cataract surgery on the measurement results. thesis.doctoral thesis, Universität Leipzig, 2015. https://nbn-resolving.org/urn:nbn:de:bsz:15-qucosa-172371