Back to search

Universität Leipzig

Individualisierte kardiale Resynchronisationstherapie mit Implantation der linksventrikulären Elektrode an die Stelle der spätesten mechanischen Aktivierung

Abstract

dc:description.abstract

Aims: Non-responder rates for CRT vary from 11 to 46 %. Retrospective data imply a better outcome with stimulation of the latest contracting LV region. Our study analyzed feasibility, safety and clinical outcome of prospectively planned LV lead placement at the site of latest mechanical activation. Methods: Thirty-eight heart failure patients with CRT indication were assessed by 3D TEE and rotation angiography of the coronary sinus. Both images were merged into a single 3D-model to identify CS target veins close to the site of latest mechanical activation. Subsequently LV lead deployment was attempted at the desired target position. Patients were clinically and echocardiographically evaluated at baseline, after 3 and 6 months. Results: The area of latest mechanical activation covered 6 ± 2 segments (38 ± 13 % of LV surface) and was found lateral in 24/37 (65 %), anterior in 11/37 (30 %), inferior in 2/37 (5 %) and septal in 1/37 (3 %) patients. In 36/37 (97 %) patients an appropriate target vein was identified and successful implantation could be performed in 34/37 (92%) patients. Among those patients clinical and echocardiographic response was observed in 91 % and 81 %, respectively. Conclusions: Individualized lead placement at the latest contracting LV site can be performed safely and successfully in the majority of patients. Initial clinical outcome data are encouraging. Identification of target sites requires multimodality integration between LV wall motion data and CS anatomy. Future developments need to improve those technologies and require randomized data on clinical outcome parameters.

Degree

thesis:*
Level thesis:degree_level
thesis.doctoral
Department thesis:degree_department
Medizinische Fakultät
Grantor dc:publisher
Universität Leipzig
Year dc:date.issued
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Döring, Michael
Advisor dc:contributor.advisor
  • Piorkowski, Christopher

Subjects

dc:subject × 2

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • free
  • info:eu-repo/semantics/openAccess
Language dc:language.dcterms_iso639_2
ger

Identifiers

dc:identifier.*
Persistent identifier dc:identifier.urn
https://nbn-resolving.org/urn:nbn:de:bsz:15-qucosa-143265

Chain of custody

source
Harvested from
QUCOSA
Base URL
www.qucosa.de/oai/
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Döring, Michael. Individualisierte kardiale Resynchronisationstherapie mit Implantation der linksventrikulären Elektrode an die Stelle der spätesten mechanischen Aktivierung. thesis.doctoral thesis, Universität Leipzig, 2014. https://nbn-resolving.org/urn:nbn:de:bsz:15-qucosa-143265