Universität Leipzig
MORPHOMETRIC ANALYSIS OF THE SHEEP THORACOLUMBAR SPINE USING COMPUTED TOMOGRAPHY AND A COMPARISON WITH THE HUMAN CORRELATE
Abstract
dc:description.abstractSheep are commonly used as animal model for in vivo testing of new spinal implants as well as surgical procedures. Therefore, extensive knowledge of the precise morphometry and biomechanics features of sheep spine is crucial for experimental design and interpretation of results obtained in these trials. Little is known about the sheep spine. Therefore, the current study, which comprises of two parts, aimed to gain more knowledge concerning the morphometry of sheep thoracolumbar spine. The first part aimed to document the morphometry of the sheep thoracolumbar vertebrae and to assess the feasibility of using sheep lumbar vertebrae as a model for human spine researches based on morphometric comparison. For this reason, computed tomographic (CT) scanning was carried out in five clinically healthy female Merino sheep (2 years, 62 ± 5.3 kg) under general anaesthesia. CT images were reformatted with 1-mm slice thickness from T2 through L6. The CT images were reformatted in transverse and sagittal planes using multiplaner reconstruction algorithm. Subsequently, CT images were transferred to a workstation and reviewed with dedicated software for measuring the dimensions of the vertebral bodies, spinal canal, intervertebral disc, and pedicles. Based on the generated morphometric data of the sheep lumbar vertebrae, four spinal indices and Pavlov’s ratio were calculated as well as the volume of the vertebral bodies. The spinal indices were concavity index, endplate index, spinal canal index and pedicle index. For measuring vertebral body volume, the transverse CT data were reformatted in 5-mm slice thickness and imported in dedicated software. Thereafter, the four spinal indices and the volume were compared to human published data. The parameter was defined comparable if the ratio sheep/human of each individual vertebra showed variation less than 20%. The second part of the current work aimed to provide quantitative morphometric data of the thoracolumbar dural sac and describe the anatomical relationship between the dural sac and its surrounding osseous structures of the spine. To achieve these aims, computed assisted myelography was carried out in five adult female blackhead sheep (2.0 ± 0.4 years, 80.6 ± 28.7 kg) under general anaesthesia. Transverse images were acquired with 2-mm slice thickness from T1 to L6. Sagittal and transverse diameters and cross-sectional area of the dural sac and the spinal canal were measured on CT images. To determine the anatomical relationship between the dural sac and osseous structures of spinal canal, the pedicle-dural sac distance and available space for dural sac were calculated. The morphometric data showed that the sheep thoracolumbar vertebral bodies and the spinal canal were wider than they were deep, most obviously in the lumbar vertebrae. The intervertebral discs were as much as 57.4% thicker in the lumbar than in the thoracic spine. The pedicles were higher and longer than they were wide over the entire thoracolumbar spine. Compared to humans, sheep lumbar vertebral body volumes were 48.6% smaller. The comparison of absolute values between both species revealed that sheep had smaller, longer and narrower vertebral bodies, thinner intervertebral discs, narrower spinal canal and narrower, higher pedicles. The comparison of the spinal indices showed a good comparability to human in terms of the vertebral endplate and spinal canal. The results of the second parts showed that the dural sac area covered 45.9% and 49.0% of the thoracic and lumbar vertebral canal area, respectively, and it is significantly (positive) correlated with the transverse diameter as well as area of the vertebral canal. The pedicledural sac distance in the lumbar vertebrae was up to 15.8% larger than in the thoracic ones. The clinical relevance of the current study, the sheep lumbar spine has good comparability to that of humans in terms of the vertebral endplate regions and spinal canal, suggesting that a sheep spinal model would be appropriate for studying artificial intervertebral discs, implantation of intervertebral fusion, etc. With regard to sheep pedicles, can be used as a model for spinal implant conditioned by adaptation of implant size to sheep pedicel dimensions. The lumbar vertebral canal shows more space for the dural sac, which seems to be safer for testing fixation spinal implants.
Degree
thesis:*- Level thesis:degree_level
- thesis.doctoral
- Department thesis:degree_department
- Large Animal Clinic for Surgery, Faculty of Veterinary Medicine
- Grantor dc:publisher
- Universität Leipzig
- Year dc:date.issued
- 2014
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Mageed, Mahmoud
Subjects
dc:subject × 10Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- free
- info:eu-repo/semantics/openAccess
- Language dc:language.dcterms_iso639_2
- eng
Identifiers
dc:identifier.*- Persistent identifier dc:identifier.urn
- https://nbn-resolving.org/urn:nbn:de:bsz:15-qucosa-155677