Back to search

Universität Leipzig

Validierung einer neuen Software für halbautomatische Volumetrie – ist diese besser als manuelle Messungen?

Abstract

dc:description.abstract

This study compared a manual program for liver volumetry with a semiautomated software. The hypothesis was that the software would be faster, more accurate and less dependent on the evaluator’s experience. Materials and Methods: Ten patients undergoing hemihepatectomy were included into this IRB approved study after written informed consent. All patients underwent a preoperative abdominal CTScan, which was used for whole liver volumetry and volume prediction for the liver part to be resected. Two different softwares were used: 1) manual method: borders of the liver had to be defined per slice by the user; 2) semiautomated software: automatic identification of liver volume with manual assistance for definition of Couinaud-segments. Measurements were done by six observers with different experience levels. Water displacement volumetry immediately after partial liver resection served as gold standard. The resected part was examined with a CT-scan after displacement volumetry. Results: Volumetry of the resected liver scan showed excellent correlations to water displacement volumetry (manual: ρ=0.997; semiautomated software: ρ=0.995). Difference between the predicted volume and the real volume was significantly smaller with the semiautomated software than with the manual method (33 % vs. 57 %, p=0.002). The semiautomated software was almost four times faster for volumetry of the whole liver. Conclusion: Both methods for liver volumetry give an estimated liver volume close to the real one. The tested semiautomated software is faster, more accurate in predicting the volume of the resected liver part, gives more reproducible results and is less dependent on the user’s experience.

Degree

thesis:*
Level thesis:degree_level
thesis.doctoral
Department thesis:degree_department
Medizinische Fakultät
Grantor dc:publisher
Universität Leipzig
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Noschinski, Leonie
Advisors dc:contributor.advisor
  • Kahn, Thomas
  • Stumpp, Patrick

Subjects

dc:subject × 11

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • free
  • info:eu-repo/semantics/openAccess
Language dc:language.dcterms_iso639_2
ger

Identifiers

dc:identifier.*
Persistent identifier dc:identifier.urn
https://nbn-resolving.org/urn:nbn:de:bsz:15-qucosa-210703

Chain of custody

source
Harvested from
QUCOSA
Base URL
www.qucosa.de/oai/
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Noschinski, Leonie. Validierung einer neuen Software für halbautomatische Volumetrie – ist diese besser als manuelle Messungen?. thesis.doctoral thesis, Universität Leipzig, 2016. https://nbn-resolving.org/urn:nbn:de:bsz:15-qucosa-210703