Back to search

Universität Leipzig

Influence of Soot on the Transport Mechanisms inside the Filter Wall of SCR-Coated Diesel Particulate Filters

Abstract

dc:description.abstract

The effect of soot on the catalytic properties of a diesel particulate filter coated with a catalyst for the selective catalytic reduction of NOx with ammonia (SDPF) was studied by means of model-gas experiments. After loading of the SDPF with model soot from 0 to 10 g l-1, the NH3 storage as well as the catalytic DeNOx behavior of the standard SCR reaction was investigated. The model soot present in the filter was shown to have an NH3 storage capacity. The soot deposit inside the SDPF filter wall lead to a decreased NO conversion in SCR experiments of up to 20 %. The NH3 breakthrough was found to be shifted towards earlier time-on-stream during NH3 adsorption on soot loaded SDPF samples. Both effects could be attributed to a diffusive mass transport limitation of the gas species through the soot to reach at the chemically active sites inside SDPF filter wall. The self-diffusion coefficient of NH3 probe molecules within a soot layer could be measured using Pulsed Field Gradient-NMR technique. The unit collector model is capable of describing the backpressure upon soot loading with a depth filtered (inside filter wall) soot amount of 1 g l-1 and 0.36 g l-1, respectively, for both SDPF types under investigation. Based on Scanning Electron Microscopy (SEM) investigation a 1-D microscopic soot filter wall-model was set up. The model implies soot as diffusion barrier for mass transport. It was calibrated based on experimental observations and allows to conclude on the distribution of the soot within the filter wall. Thus, a high soot-coverage of the porous filter wall close to the inlet channel, a slightly covered middle part and a soot free zone close to the outlet explains the observed reduction in NO conversion as well as the NH3 breakthrough at earlier time-on-stream during NH3 adsorption experiments for SDPF samples loaded with soot. A modelled homogeneous soot distribution (0.6 µm soot layer on top of washcoat) within the whole SDPF was shown to result in NO conversion drop up to 45 %.

Degree

thesis:*
Level thesis:degree_level
thesis.doctoral
Grantor dc:publisher
Universität Leipzig
Year dc:date.issued
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Purfürst, Marcus

Subjects

dc:subject × 7

Rights

dc:rights
Statement dc:rights
  • info:eu-repo/semantics/openAccess
Language dc:language.dcterms_iso639_2
eng

Identifiers

dc:identifier.*
URN
urn:nbn:de:bsz:15-qucosa2-211594

Chain of custody

source
Harvested from
QUCOSA
Base URL
www.qucosa.de/oai/
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation