Back to search

Technische Universität Dresden

Electron multiplying CCD – based detection in Fluorescence Correlation Spectroscopy and measurements in living zebrafish embryos

Abstract

dc:description.abstract

Fluorescence correlation spectroscopy (FCS) is an ultra-sensitive optical technique to investigate the dynamic properties of ensembles of single fluorescent molecules in solution. It is in particular suited for measurements in biological samples. High sensitivity is obtained by employing confocal microscopy setups with diffraction limited small detection volumes, and by using single-photon sensitive detectors, for example avalanche photo diodes (APD). However, fluorescence signal is hence typically collected from a single focus position in the sample only, and several measurements at different positions have to be performed successively. To overcome the time-consuming successive FCS measurements, we introduce electron multiplying CCD (EMCCD) camera-based spatially resolved detection for FCS. With this new detection method, multiplexed FCS measurements become feasible. Towards this goal, we perform FCS measurements with two focal volumes. As an application, we demonstrate spatial cross-correlation measurements between the two detection volumes, which allow to measure calibration-free diffusion coefficients and direction-sensitive processes like molecular flow in microfluidic channels. FCS is furthermore applied to living zebrafish embryos, to investigate the concentration gradient of the morphogen fibroblast growth factor 8 (Fgf8). It is shown by one-focus APD-based and two-focus EMCCD-based FCS, that Fgf8 propagates largely by random diffusion through the extracellular space in developing tissue. The stable concentration gradient is shown to arise from the equilibrium between a local morphogen production and the sink function of the receiving cells by receptor-mediated removal from the extracellular space. The study shows the applicability of FCS to whole model organisms. Especially in such dynamically changing systems in vivo, the perspective of fast parallel FCS measurements is of great importance. In this work, we exemplify parallel, spatially resolved FCS by utilizing an EMCCD camera. The approach, however, can be easily adapted to any other class of two-dimensional array detector. Novel generations of array detectors might become available in the near future, so that multiplexed spatial FCS could then emerge as a standard extension to classical one-focus FCS.

Degree

thesis:*
Level thesis:degree_level
thesis.doctoral
Department thesis:degree_department
Fakultät Mathematik und Naturwissenschaften
Grantor dc:publisher
Technische Universität Dresden
Year dc:date.issued
2010

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Burkhardt, Markus
Advisor dc:contributor.advisor
  • Schwille, Petra

Subjects

dc:subject × 5

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • free
  • info:eu-repo/semantics/openAccess
Language dc:language.dcterms_iso639_2
eng

Identifiers

dc:identifier.*
Dc Publisher Identifier
4519974-7
Ddb Identifier Erstkat Id
331316048

Chain of custody

source
Harvested from
QUCOSA
Base URL
www.qucosa.de/oai/
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Burkhardt, Markus. Electron multiplying CCD – based detection in Fluorescence Correlation Spectroscopy and measurements in living zebrafish embryos. thesis.doctoral thesis, Technische Universität Dresden, 2010. https://nbn-resolving.org/urn:nbn:de:bsz:14-qucosa-61021