Back to search

Technische Universität Dresden

A study on Textile Reinforced - and Expanded Polystyrene Concrete sandwich beams

Abstract

dc:description.abstract

Textile Reinforced Concrete (TRC) with a small thickness, high tensile and compressive strength has been combined with lightweight materials to create sandwich elements. Due to the low strength of the core materials in the sandwich elements, the additional shear connector devices were suggested to improve the load capacity. However, it raised an idea of using a higher strength material core, Expanded Polystyrene Concrete (EPC), without any connector devices to create a new type of lightweight sandwich element, which can be an answer for not only developing lightweight structures but also solving environmental problems. In this thesis, this novel idea was gradually realized with a study on TRC-EPC sandwich beams. Firstly, experimental material tests on EPC showed the possibility to recycle EPS waste for EPC with a density of around 950 kg/m3. Thus, an EPC with a density of 920 kg/m3 and a compressive strength of 5.2 N/mm2 was chosen for the core to realize the concept for TRC-EPC sandwich with 18 experimental beams. Bending tests of six series with shear-to-depth-ratio (a/d) from 1.5 to 5.2 were implemented to study load responses of this type of sandwich beam. The failure moments of all the specimens were smaller than the nominal moment strength of the cross section. The load capacities of the specimens depend strongly on the ratio a/d. The calculations for the shear capacity according to standards as well as shear calculation approaches were implemented. Due to their generalized form, ACI 318-05 and EC2 offer conservative results for a/d<5.2. The dependence of the shear capacity on a/d could be better described with CEB-FIB Model Code 1990. For the beams with 1.5<a/d and a/d<2.1, Strut and Tie Model gave the most suitable results. In case a/d>2.1, ZINK’s model offered better results than the others. Besides, a new proposed equation for the shear capacity of TRC-EPC sandwich beams depending on the a/d was also suggested. In order to model the load response of the six experimental series, FEM models with ATENA developed. The models with and without a consideration of the bond between the textile and fine HSC in the TRC layer underestimated the load capacity with tolerance 26% and 28 % respectively. The tolerances for the deflections in the models with a/d>2.5 were around 22 % and 23%. Finally, an engineering model originally based on sandwich theory was developed to model the load-deflection response of this type of sandwich beams. The model could predict the displacement with tolerances from -24 % to 12 %. The load capacity of TRC-EPC sandwich beams was underestimated with a tolerance in the range of 15- 34 %.

Degree

thesis:*
Level thesis:degree_level
thesis.doctoral
Department thesis:degree_department
Fakultät Bauingenieurwesen
Grantor dc:publisher
Technische Universität Dresden
Year dc:date.issued
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Nguyen, Viet Anh

Subjects

dc:subject × 9

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • free
  • info:eu-repo/semantics/openAccess
Language dc:language.dcterms_iso639_2
eng

Identifiers

dc:identifier.*
Dc Publisher Identifier
4519974-7
Ddb Identifier Erstkat Id
443475237

Chain of custody

source
Harvested from
QUCOSA
Base URL
www.qucosa.de/oai/
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Nguyen, Viet Anh. A study on Textile Reinforced - and Expanded Polystyrene Concrete sandwich beams. thesis.doctoral thesis, Technische Universität Dresden, 2015. https://nbn-resolving.org/urn:nbn:de:bsz:14-qucosa-158948