Back to search

Technische Universität Dresden

Hydrodynamics in the Calibration of Optical Tweezers for Coiled-Coil Studies

Abstract

dc:description.abstract

Coiled-coil motifs are part of 5–10 % of the eukaryotic proteome and are involved in important cellular processes such as membrane trafficking, chromosome segregation or mechanosensing. Their canonical form is well understood and based on a heptad repeat with hydrophobic amino acids at positions 1 and 4. A sequence of these peptides folds into an α-helix and two, or more, of these helices bind together by winding around each other, covering up the hydrophobic residues and giving rise to the coiled-coil structure. Coiled-coil proteins appearing in nature do, however, deviate from this form by introducing discontinuities into the heptad repeat. The effect of these imperfections on the structure is only known for few cases and not generally understood or predictable. The additional impact of these discontinuities on the dynamic function of coiled-coil domains is unknown altogether. Here, in order to tackle these questions, the adhesive forces between the α-helices are studied in single-molecule experiments. To measure these small forces (∼ pN) with a high spatial and temporal resolution, a dual-trap optical tweezers setup was constructed. Special emphasis was put on realizing the required high resolution, a large degree of automation and versatility during the building process. The instrument’s performance was assessed by recording force-extension curves of DNA yielding results for the molecular parameters persistence length and stretch modulus in good agreement with those found in the literature. Additionally, the Allan deviation was computed for different configurations of beads and a high stability and resolution of the instrument was found with optimal performance on the time scale of 1–10 s. Optical tweezers require calibration to accurately measure forces. To this end, generally a scheme is used that leverages the Brownian motion of a trapped object in the harmonic potential, created by the laser focus, to determine the parameters required to convert the analog voltage signal to distances and forces. However, this approach requires prior knowledge of the bead’s drag coefficient. A method was suggested previously that allows to measure this parameter by exciting the trapped bead through an external fluid flow and observing its response. Yet, this scheme was proposed for single-trap devices only. The precision and versatility of the new instrument was increased by extending this technique to work with two traps and implementing it in the apparatus. To this aim, the underlying equations of a trapped bead’s motion were modified to include hydrodynamic interactions between the objects resulting from the external fluid flow. It was found that a single multiplicative factor is sufficient to correct the calibration results for the hydrodynamic effects and ensure precise calibration. The drag coefficient of several beads yielded the same result for a single and two traps within the measurement error thus confirming the validity of the method. The newly built instrument was then used to study the coiled-coil protein early endosome antigen 1 (EEA1). This 200 nm long homodimer was shown to undergo an entropic collapse upon binding a small GTPase at the N-terminus. For further investigations of this effect and the adhesives forces at play, an experiment was designed here to unzip the two α-helices of the protein. To this end, DNA handles were attached to each of the two helices using a sortase A based ligation reaction as force moderators and first optical tweezers experiments were performed with the protein-DNA chimera. Thus, the necessary tools for unzipping assays of EEA1 are now at hand to further research the entropic collapse process. To summarize, a dual-trap optical tweezers setup was built, the calibration routine extended and realized in a more precise way and the instrument was used to investigate binding energies of EEA1 α-helices.

Degree

thesis:*
Level thesis:degree_level
thesis.doctoral
Department thesis:degree_department
Fakultät Physik
Grantor dc:publisher
Technische Universität Dresden
Year dc:date.issued
2019

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ehrlich, Christoph

Subjects

dc:subject × 7

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • free
  • info:eu-repo/semantics/openAccess
Language dc:language.dcterms_iso639_2
eng

Identifiers

dc:identifier.*
Dc Publisher Identifier
2024114-8
Ddb Identifier Erstkat Id
168371069X

Chain of custody

source
Harvested from
QUCOSA
Base URL
www.qucosa.de/oai/
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Ehrlich, Christoph. Hydrodynamics in the Calibration of Optical Tweezers for Coiled-Coil Studies. thesis.doctoral thesis, Technische Universität Dresden, 2019. https://nbn-resolving.org/urn:nbn:de:bsz:14-qucosa2-360984