Technische Universität Dresden
Analytical determination of emerging contaminants by using a new graphene-based enrichment material for solid-phase extraction and passive sampling
Abstract
dc:description.abstractEmerging contaminants represent newly identified organic chemical pollutants that are not yet covered by routine monitoring and regulatory programs. Current research on these contaminants is greatly hindered by the shortage of analytical methods due to the complex matrices, extremely low concentration and their “emerging” nature. In this study the innovative analytical and monitoring methods have been developed and validated for determination of emerging pollutants in water (including pharmaceutical and personal care products, pesticides and artificial sweeteners) based on graphene-silica composite as the solid-phase extraction (SPE) sorbent and as the receiving phase in passive sampler. Graphene, a new allotropic member in the carbon family, has been considered to be a promising candidate for sorption material with high loading capacity because of its ultra-high specific surface area and large delocalized π-electron-rich structure. The composite employed in this work was synthesized by using the cross-link agent to covalently combine carboxylic acid groups of graphene-oxide with the amino groups of the modified silica gel. Afterwards, graphene-silica composite was obtained after treated with hydrothermal reaction in the microwave autoclave, which was demonstrated by X-ray diffraction (XRD). The analytical procedure entails SPE followed by high performance liquid chromatography equipped with tandem mass spectrometers (HPLC-MS/MS). Several crucial parameters were optimized to improve recovery of the analytes, including the amount of sorbents, the ratio of graphene oxide/amino-silica and pH value of water samples. The best recovery results were achieved with 100 mg 10 % (w/w) graphene-silica composite, which were over 70 % except four artificial sweeteners, ranitidine and triclosan. Compared with its commercial counterpart Oasis HLB, pH value variation of water samples has less effect on the recoveries, making graphene composite to be a potential receiving phase of monitoring tool. The batch-to-batch reproducibility was verified on six independently SPE cartridges with graphene-silica composites from two repeatable synthetic batches, showing relative standard deviations (RSDs) in the range of 8.3 % to 19.1 %, except ibuprofen and saccharin. The cartridges proved to be reusable for at least 10 times consecutive extractions, with RSD < 14.9 %, except ibuprofen and diclofenac. The Chemcatcher® passive sampler is frequently used for monitoring polar organic chemicals in surface water. Uptake kinetics is necessary to be quantified to calculate time-weighted average (TWA) concentration. A series of calibration experiments were conducted in the beaker renewal experiments as well as in the flow-through system with styrenedivinylbenzene-cross connect (SDB-XC) disks and graphene-silica composite as the receiving phase. The results obtained from the beaker renewal experiments showed that the uptake kinetics of accumulated compounds with all Chemcatcher® configurations can keep linear within 2 weeks. The innovative configuration using graphene-silica composite powder placed between two PES membranes was able to accumulate eleven of the selected compounds with uptake rate (Rs) from 0.01 L/day (acesulfame K and sucralose) to 0.08 L/day (chlothianidin), while its commercial counterpart SDB-XC disks with polyethersulfone (PES) membranes can accumulate seven substances with Rs from 0.02 L/day (sucralose and chlothianidin) to 0.15 L/day (carbamazepine). In the flow-through system, when Chemcatchers® were equipped with SDB-XC disks without PES membranes, the linear uptake range for the majority of compounds was only in one week, except atrazine. The Rs of accumulated compounds were from 0.16 L/day (chloramphenicol) to 1.04 L/day (metoprolol) that are higher than the same substances in the beaker renewal experiments, in which the Rs of chloramphenicol and metoprolol were 0.09 L/day and 0.56 L/day respectively. However, if the PES membranes were employed, the uptake kinetics in both calibration experimental designs were comparable: the Rs of accumulated compounds from the configuration with SDB-XC disks covered by PES membranes were from 0.035 L/day (sucralose) to 0.17 L/day (carbamazepine) and from the configuration with graphene-silica composite were from 0.01 L/day (gemfibrozil) to 0.08 L/day (chlothianidin). Moreover, the uptake range can keep linear within two weeks. The developed Chemcatcher® method was successfully applied in real surface waters. 1-H benzontriazole, tolyltriazole and caffeine were the main contaminants in Elbe River and the Saidenbach drinking water reservoir. The investigated results between summer and autumn monitoring period were not significantly different.
Degree
thesis:*- Level thesis:degree_level
- thesis.doctoral
- Department thesis:degree_department
- Fakultät Umweltwissenschaften
- Grantor dc:publisher
- Technische Universität Dresden
- Year dc:date.issued
- 2020
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Liu, Yang
Subjects
dc:subject × 10Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- free
- info:eu-repo/semantics/openAccess
- Language dc:language.dcterms_iso639_2
- eng
Identifiers
dc:identifier.*- Dc Publisher Identifier
- 2024114-8
- Ddb Identifier Erstkat Id
- 1738938751