Abstract
dc:description.abstractA novel combination of a full-field X-ray detector and particle-induced X-ray emission (PIXE) as an established analytical method has been assembled and examined at the Helmholtz-Zentrum Dresden-Rossendorf (HZDR). The so-called Colour X-ray Camera (CXC) based on a pn-junction charge-coupled device (pnCCD) is interconnected with a poly-capillary optics (PCO) for the purpose of X-ray imaging. This first combination of PIXE as a lowbackground excitation method and the approach of full-field imaging is likely to close the gap between fast and sensitive investigations of large sample surfaces. The assembly called full-field PIXE (FF-PIXE) is intended for laterally resolved and quantifiable surveys of large geological samples with respect to their trace elemental composition. The PCO comprising hundred thousands of capillaries with inner diameters of about 20 µm is employed in order to map the specimen’s characteristic X-ray response induced by 3 MeV protons provided by a 6 MV tandem-accelerator. The subsequent pnCCD-chip comprising 264×264 pixels is capable of individually detecting X-ray photons in the energy range from 1 to 20 keV on a 12×12 mm² large field of view. The camera’s native lateral resolution could be determined to be 76 µm in the medium energy range, which is basically restricted by the pixel dimensions (48×48 µm²). Extensive experimental tests investigating the concept of sample 'illumination', X-ray transmission through the PCO, and imaging properties of the CXC, yielded substantial insights allowing to judge the new concept of X-ray imaging. While the variability of excitation intensity was proven to be better than 10% and the homogeneous response of the detector was verified, energy-dependent imaging impairments arose from the PCO. In comparative measurements at imaging systems using photons and electrons for excitation, both the full field approach and PIXE as the method of choice could be confirmed to be capable of meeting the initial objectives. In addition, enhancement techniques have been successfully tested to overcome downsides arising from the PCO’s transmission characteristics. Apart from suppressing the hexagonal pattern and a radial unevenness caused by the PCO, the system’s lateral resolving power could be improved towards 63 µm when using the 1:1 optics. The investigations have revealed that, at present, the complex transmission nature of the PCO is a main obstacle in obtaining quantitative results. A number of parameters (e.g. frame readout speed) and dependencies (e.g. lateral resolution vs. elemental sensitivity) have nevertheless been identified and explored the understanding of which will help to move forward 'on the road to metrology'.
Degree
thesis:*- Level thesis:degree_level
- thesis.doctoral
- Department thesis:degree_department
- Physik
- Grantor dc:publisher
- Technische Universität Dresden
- Year dc:date.issued
- 2021
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Buchriegler, Josef
Subjects
dc:subject × 11Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- free
- info:eu-repo/semantics/openAccess
- Language dc:language.dcterms_iso639_2
- eng
Identifiers
dc:identifier.*- Dc Publisher Identifier
- 2024114-8
- Ddb Identifier Erstkat Id
- 1759602337