Back to search

Universität Leipzig

Particle Exposure in German Dwellings: Particle Number and Mass Size Distributions, Indoor Particle Dynamics, and Source Apportionment

Abstract

dc:description.abstract

Exposure to aerosol particles can cause health issues such as respiratory and cardiovascular diseases. Nevertheless, aerosol particle exposure with size-resolved information was seldom investigated in real-life European houses in the long term, especially for the ultrafine size range. In this work, indoor and outdoor measurements were conducted from December 2016 to March 2019. A standard of high-quality indoor and outdoor particle measurements in multi-homes was established for the first time. For more than 500 days, measurement data were collected in 40 German homes, including particle mass concentrations (PMC) of PM10, PM2.5, and PM1, particle number concentration (PNC) and size distribution, equivalent black carbon (eBC) mass concentration, CO2 concentration, and the residents’ activity log. With such novel dataset, representative patterns of diurnal and seasonal variation of particle concentration and size distribution as well as eBC mass concentration have been captured. In the warm season, diurnal cycles of indoor PMC and PNC showed weaker variation and less intense peaks (around the time of breakfast, lunch and dinner) than in the cold season, due to ventilation reducing the effect of indoor sources. To better understand the key dynamic processes of indoor particles (i.e. ventilation, building shell penetration, particle losses and emission), two commonly used quantitation methods, single parameter approach (SPA) and Indoor Aerosol Model approach (IAM), were compared and evaluated for the first time. Correction factors were derived to adjust the emission rates calculated from the simplified SPA approach, making emission rates derived from different levels of analysis mutually comparable. Results show that indoor source was the major contributor (56%) to indoor particle number exposure in investigated German residences. For the contribution of outdoors, penetration through the building envelope (26%) was higher than infiltration through open windows (15%). Burning candles and opening of window(s) led to seasonal differences in the contributions of indoor sources to residential exposure (70% and 40% in the cold and warm season, respectively). Indoor sources should be taken into consideration in future epidemiological studies and risk assessment of exposure to particle air pollution.

Degree

thesis:*
Level thesis:degree_level
thesis.doctoral
Department thesis:degree_department
Fakultät für Physik und Geowissenschaften
Grantor dc:publisher
Universität Leipzig
Year dc:date.issued
2021

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Zhao, Jiangyue

Subjects

dc:subject × 5

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • free
  • info:eu-repo/semantics/openAccess
Language dc:language.dcterms_iso639_2
eng

Identifiers

dc:identifier.*
Dc Publisher Identifier
30026-3

Chain of custody

source
Harvested from
QUCOSA
Base URL
www.qucosa.de/oai/
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Zhao, Jiangyue. Particle Exposure in German Dwellings: Particle Number and Mass Size Distributions, Indoor Particle Dynamics, and Source Apportionment. thesis.doctoral thesis, Universität Leipzig, 2021. https://nbn-resolving.org/urn:nbn:de:bsz:15-qucosa2-767133