Technische Universität Dresden
Influence of Harmonic Distorted Voltages on the Dielectric Behaviour of Polymeric Insulation Materials
Abstract
dc:description.abstractThe shift from centralized to distributed generation of energy and increasingly flexible electrical equipment brings a large number of power converters into the energy systems. Such power electronics-based applications may provoke harmonic distortion of the system voltage if they are not properly filtered or if resonance effects occur. The latter can be caused by the interplay of inductive and capacitive components as well as parasitic properties leading to additional capacitances. Single frequencies can then be extraordinarily amplified, resulting in the distortion of voltage waveforms. This thesis aims to analyze some of the major effects of harmonic voltage distortion on typical polymeric insulation materials that are utilized in medium-voltage applications. These principal effects of voltage distortion range from additional dielectric losses in insulation materials causing dielectric heating to the altered partial discharge (PD) behaviour. For the experiments and calculations, typical harmonic distorted voltages in the frequency range up to 1550 Hz (31st harmonic) with a total harmonic distortion up to 20 % are utilized. To achieve the goals of this thesis, several test setups, methods and models have been developed, implemented, verified and tested. Especially the generation of harmonic distorted voltages up to several 10 kV is challenging when using conventional laboratory equipment. Besides the factual results that are explained in this thesis, the developed methods and verified models as well as the utilized parameters provide a framework for subsequent investigations. Several methods to quantify the dielectric losses under harmonic distorted voltages are introduced, compared and experimentally verified on epoxy polymer samples. One of the methods, the direct power measurement method, allows to measure the dielectric losses under high electrical field strength and harmonic distortion simultaneously. Other methods rest upon the spectral decomposition into single frequency components and then the superimposition of each dielectric loss proportion. The experiments on epoxy polymer samples show that the deviation between the methods is within the inaccuracy of the measurement systems. The direct power measurement method is especially useful for so-called nonlinear materials with electrical field-dependent dielectric properties. For these materials, spectral decomposition is not feasible as the electrical field conditions dominate the dielectric loss behaviour. The influence of different electrical field strength magnitudes and of the temperature is quantified for the specified epoxy polymer using the direct power measurement method. The material under investigations has very low dielectric losses and even at temperatures close to the glass transition of the epoxy polymer, the danger of thermal runaway is low. The dielectric losses themselves are of course increasing with higher electrical field strength, but the measurements show clearly that the behaviour is predictable even with harmonic distortion. A developed thermo-electrical multi-frequency model allows to calculate the dielectric heating and hence the temperature increase due to harmonic voltage distortion. The calculations are carried out for two materials: epoxy polymer as a low-loss dielectric and phenolic paper (FR2) which inhibits high dielectric losses. The temperature increase due to the dielectric losses (regardless of harmonic distortion) is below 1 K for epoxy polymer. On the contrary, phenolic paper heats up by up to 15 K for the observed geometry and boundary conditions. Harmonic distortion in that case accounts for up to +55 % of temperature increase, when compared to a purely sinusoidal voltage with the fundamental frequency. Thermal breakdown measurements of both materials, epoxy polymer and phenolic paper, verify the calculated heating. The breakdown field strength of epoxy resin is independent of the harmonic distortion and no thermal breakdown was triggered. On the other hand, with higher frequency distortion the required thermal breakdown field strength in phenolic paper decreases significantly. The calculations of the developed model were hence verified indirectly. Besides dielectric losses, it is known that harmonic distortion influences the PD behaviour. With the intention of a quantitative analysis, surface discharges on a PET foil triggered by a sphere-plate electrode arrangement are measured. The PD characteristics such as apparent charge Q and PD repetition rate n are investigated using a constant voltage amplitude for different harmonic distorted waveforms and hence focussing on the voltage shape-distorting effect of the harmonics. With increasing harmonic order h, the apparent charge tends to decrease while the repetition rate increases. Additionally, the phase-resolved PD patterns are analyzed in a way that the repeated inception and extinction of PD within one voltage period can be quantified by a so-called phase interval with PD. The harmonic distortion of the voltage affects the total length of the interval and hence the time within one period in which PD are active. Differently distorted voltages do not influence the PD inception voltage. Constant peak voltage tests using the identical electrode arrangement lead to the conclusion that neither the total harmonic distortion (THD) or the harmonic order have an unambiguous impact on PD aging. There is no statistically significant correlation between the altered PD characteristics and the measured lifetime of the Polyethylene terephthalate (PET) foil samples in the context of harmonic distortion. The presented thesis demonstrates that moderately distorted voltages which stress modern polymeric insulation materials do not pose a severe problem for longevity and reliability of insulation systems. The described results, but also the test setups, methods and models hence provide a basis for subsequent edge case investigations for more specific applied problems.
Degree
thesis:*- Level thesis:degree_level
- thesis.doctoral
- Department thesis:degree_department
- Fakultät Elektrotechnik und Informationstechnik
- Grantor dc:publisher
- Technische Universität Dresden
- Year dc:date.issued
- 2024
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Linde, Jan Thomas
- Advisor dc:contributor.advisor
-
- Großmann, Steffen
Subjects
dc:subject × 10Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- free
- info:eu-repo/semantics/openAccess
- Language dc:language.dcterms_iso639_2
- eng
Identifiers
dc:identifier.*- Dc Publisher Identifier
- 2024114-8
- Ddb Identifier Erstkat Id
- 1913937828