Technische Universität Chemnitz
Design of Optimized Broadband Excitation Signals for Consistent Impedance Spectroscopy Measurements
Abstract
dc:description.abstractFor consistent electrochemical impedance spectroscopy (EIS) measurements, several important conditions must be met. The measurements should be made in a linear region of the characteristic of the Device Under Test (DUT), which should be kept causal and stable throughout the measurement time. Violation of these conditions requires extensive special signal processing or can invalidate the entire measurement. As the measurement procedure consists of applying an excitation signal and measuring the response signal, the excitation signal plays a critical role in the quality of the measurement. It should have a small amplitude to meet the linearity and stability conditions while maintaining a sufficient signal-to-noise ratio. This is particularly important for electrochemical systems, which change their state during long measurement times for low frequency excitations. Multi-frequency signals, such as multisine signals, outperform sine-sweep signals in meeting these conditions because they include multiple frequencies within the same signal and can, therefore, significantly reduce measurement time. These signals must be optimized to ensure that the amplitude remains within the linearity range and that the signal power density per frequency is maximized. Until now, optimization procedures have been performed primarily for the requirements of specific applications, resulting in the lack of a universal methodology. In this thesis, we propose, for the first time, a novel methodology for designing multisine signals, reducing measurement time, maximizing the excitation signal power, maintaining the linearity range, and thereby ensuring system stability even at low frequencies in the mHz range. Within a comprehensive approach, various aspects are considered, such as optimizing the frequency selection, reducing the signal duration, and maintaining the linearity range. To evaluate the consistency of measured impedance spectra, we propose a novel method based on the regularized linear Kramers-Kronig (rLKK), which is robust to distortions and noise. Three novel phase optimization methods have been developed, tailored to the desired frequency density at low frequencies and the specific characteristics of the DUT. First, a combined metaheuristic gradient solution based on Role-Playing Game Theory has been developed. The advantage of this method is that it is able to search the optimum globally and is independent of the initial phase. In the second method, the optimization of the crest factor was realized based on a transformation by the generalized sigmoid function to limit the signal to the linear range, followed by clipping to eliminate the remaining peaks. Compared to common methods that rely solely on clipping, the sigmoid function offers a significant advantage. It acts as a variable multiplier, emphasizing values closer to the peaks while keeping the signal within the linear range. The third method uses a two-phase optimization approach. The first phase minimizes the peaks of battery charge variation to improve stability during the measurement. However, this can increase the crest factor of the excitation signal. The second phase minimizes the crest factor of the signal. Moreover, a stabilization method is proposed for electrochemical systems with strong transient behavior. This method involves including a dummy injection interval and considering multiple periods of the excitation signal. The determination of suitable stabilization time and the number of periods has been achieved through the use of the rLKK. The experimental validation was conducted on a lithium-ion battery cell and on bioimpedance spectroscopy, employing the Cole-Cole model. In the case of lithium-ion battery cells, it was demonstrated that the proposed excitation signals enable accurate and stable impedance measurement of the charge transfer and diffusion processes, which are critical for determining battery state of health and state of charge. With a signal duration of 100 s, six frequencies per decade, and a frequency range of 10 mHz to 1 kHz, the resulting impedance spectrum demonstrates an RMS rLKK deviation of 216 ppm. Compared to traditional sine sweep methods, it exhibits an RMS deviation of 0.02% in impedance spectra, which is a tenfold improvement over the 0.28% deviation reported in the literature. This approach achieves measurements from 3 to 9 times faster than conventional techniques with comparable accuracy. The addition of the proposed stabilization minimizes the rLKK deviation to 84 ppm, but adds 200 s to the measurement time. In the case of bioimpedance spectroscopy for measurements at six frequencies per decade in the frequency range 5 kHz to 500 kHz, the signal duration is 0.39 ms, and the total measurement time on an STM32 microcontroller is 1.53 seconds, with a maximum impedance deviation of 0.56 percent. This is at least 19 times faster than previous works and 2.67 times more accurate, as well as more robust to noise.
Degree
thesis:*- Level thesis:degree_level
- thesis.doctoral
- Department thesis:degree_department
- Fakultät für Elektrotechnik und Informationstechnik
- Grantor dc:publisher
- Technische Universität Chemnitz
- Year dc:date.issued
- 2024
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Kallel, Ahmed Yahia
- Advisor dc:contributor.advisor
-
- Kanoun, Olfa
Subjects
dc:subject × 10Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- free
- info:eu-repo/semantics/openAccess
- Language dc:language.dcterms_iso639_2
- eng
Identifiers
dc:identifier.*- Dc Publisher Identifier
- 5018951-7