Back to search

Technische Universität Dresden

Evaluation of Doppler Lidar Scan Strategies for Wind Measurements in the Atmospheric Boundary Layer

Abstract

dc:description.abstract

The simultaneous use of more than two scanning Doppler Lidar (DL) systems offers unique possibilities for the ground-based remote sensing of the three-dimensional wind field in the atmospheric boundary layer. However, experiments exploring such applications are scarce due to their high complexity and costs. In this research, we utilize data from eight DL systems together with a sonic anemometer on a tall tower to compare and combine their measurements to assess their quality. Particularly, we evaluate five different multi DL scan strategies that combine three DL systems into so-called virtual towers (VT) and investigate performance disparities between single and such triple DL setups, offering new insights into their respective advantages and disadvantages. Additionally, we conducted virtual DL measurements within a Large-Eddy Simulation (LES) framework to simulate a single and a triple DL setup and to compare those simulations with our field data. We analyze the differences of wind measurements from two different VT triple DL setups with those from a sonic anemometer located 90 m above ground on an instrumented tower and with two single DLs. The triple DL setup was operated in different step/stare and continuously moving scanning strategies, while the single DL were operated in a two different continuous scan Velocity-Azimuth-Display (VAD) modes. The instruments were deployed at the German Meteorological Service (DWD) boundary-layer field site in Falkenberg during the FESST@MOL (Field Experiment on sub-mesoscale spatio-temporal variability at the Meteorological Observatory Lindenberg) campaign from 01 June to 31 August 2020. Overall, we found good agreement between the Lidar methods and the sonic anemometer for various averaging times and scan modes, while the agreement increases with an increasing averaging time caused by a reduced random error due to a larger number of independent samples reaching comparabilities of between 0.45 m s-1 (step/stare method) and 0.92 m s-1 (continuously moving scanning strategy) at an averaging time of 30 min. While the main focus of this work is on horizontal wind speed measurements, we also show that especially the step/stare scan strategies of the first VT setup are able to reliably measure the turbulent kinetic energy and the maximum 3 s gust speed per 10 minutes (comparability of 0.826 m s-1), whereas the results of the single DL systems showed larger discrepancies (comparability of 1.65 m s-1). Moreover, we found a decreasing agreement between the single and triple Lidars with increasing height up to 495 m above ground where the comparability for the step/stare method at an averaging time of 30 min decreases to 0.78 m s-1, which can be explained by the increasing spatial averaging area, which increases with height. The single DL with the larger zenith angle exhibited poorer agreement with the triple DL setup than the one with the smaller zenith angle, particularly at higher altitudes, possibly caused by the smaller spatial area that DL needed to average over. The comparability between the single and trip DL setups for the larger zenith angle was 0.71 m s-1, compared to 0.57 m s-1 and for the smaller zenith angle. In addition to field measurements, we conducted nine idealized LES runs combined with an offline Lidar simulator tool for different combinations of atmospheric instability and thermal surface heterogeneity. Each simulation comprised ten different VTs and one VAD system. The results show that especially step/stare scan strategies of the VT setup capture the actual wind field accurately because these estimates incorporate to more sampling points than the continuously scanning strategy. Moreover, they confirm that a single Doppler Lidar provides reliable wind speed and direction data over heterogeneous but essentially flat terrain. The comparison between the simulated DLs and a simulated sonic anemometer as a reference reach similar values of comparability and bias as in the field data comparisons. They show an offset reaching comparabililties between 0.15 m s-1 and 0.40 m s-1 in triple DL and between 0.20 m s-1 and 0.60 m s-1 in single DL wind measurements at an averaging time of 10 min and the influence of horizontal distance between different measuring devices when comparing them. As expected, the LES results show a decreasing accuracy of the DL measurements with increasing atmospheric instability. No effect due to the different scale of thermal surface heterogeneity was detected.

Degree

thesis:*
Level thesis:degree_level
thesis.doctoral
Department thesis:degree_department
Umweltwissenschaften
Grantor dc:publisher
Technische Universität Dresden
Year dc:date.issued
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • von Chaulin, Kevin
Advisors dc:contributor.advisor
  • Mauder, Matthias
  • Schmid, Hans-Peter

Subjects

dc:subject × 9

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • free
  • info:eu-repo/semantics/openAccess
Language dc:language.dcterms_iso639_2
eng

Identifiers

dc:identifier.*
Dc Publisher Identifier
2024114-8
Ddb Identifier Erstkat Id
192863432X

Chain of custody

source
Harvested from
QUCOSA
Base URL
www.qucosa.de/oai/
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

von Chaulin, Kevin. Evaluation of Doppler Lidar Scan Strategies for Wind Measurements in the Atmospheric Boundary Layer. thesis.doctoral thesis, Technische Universität Dresden, 2025. https://nbn-resolving.org/urn:nbn:de:bsz:14-qucosa2-974710