Back to search

Queen's University at Kingston

Polarimeter for an Accelerated Spheromak

Abstract

dc:description.abstract

A three-beam heterodyne polarimeter has been designed and constructed to measure line-integrated density and Faraday rotation of accelerated spheromak plasmas in the Plasma Injector 1 and 2 devices (PI-1, PI-2) at General Fusion Inc. Faraday rotation is a function of the local magnetic field and electron density. Therefore, the polarimeter has the potential to provide information on the internal magnetic field of the plasma. A typical spheromak is about 1m in length and is accelerated to speeds on the order of 100km/s. At a bandwidth of 1MHz, the polarimeter can axially resolve the spheromak down to about 10cm. The polarimeter uses a \nit{CO}2 laser that produces a Faraday rotation signal of about $0.5\degrees$ for a typical plasma with density and magnetic field on the order of $\ee{21}\mmt$ and 1T. The Faraday rotation measurement noise floor for a null signal is about $0.1\degrees$. Two important sources of Faraday rotation error are the ellipticity and collinearity of the plasma-immersed beams. These error sources are examined by sending the plasma beams through a rotating optic to mimic the path through a dense, magnetized plasma. The error due to the ellipticity effect has been reduced to below the noise floor by careful alignment and use of zero phase reflectors that minimize elliptical polarization of the beams. Collinearity error has been greatly improved by aligning the beams with a rotating ZnSe wedge. Measurements after the alignment match well with a model Faraday rotation signal generated from magnetic probe measurements. However, beam collinearity continues to be a significant source of error. For regions with strong density gradients, the size of this error can be on the order of the signal magnitude. For future work, steps should be taken to improve the alignment of the two plasma-immersed beams, and to shorten the length of the beam path to further reduce the beam collinearity error.

Degree

thesis:*
Department dc:contributor.department
Physics, Engineering Physics and Astronomy
Grantor
Queen's University at Kingston
Year dc:date.issued
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Carle, Patrick
Advisor dc:contributor.supervisor
  • Morelli, Jordan E.

Subjects

dc:subject × 7

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1974/12163

Chain of custody

source
Harvested from
Queens University
Base URL
qspace.library.queensu.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Carle, Patrick. Polarimeter for an Accelerated Spheromak. Queen's University at Kingston, 2014. https://hdl.handle.net/1974/12163