Back to search

Queen's University at Kingston

Performance Analysis of a Transcritical CO2 Heat Pump Water Heater Incorporating a Brazed-Plate Gas-cooler

Abstract

dc:description.abstract

This study focuses on the experimental testing and numerical modeling of a 4.5 kW transcritical CO2 heat pump water heater at Queen’s University in the Solar Calorimetry Laboratory. Due to the predicted high heat rejection temperatures in a transcritical vapour-compression cycle, buoyancy driven thermosyphon flow through a brazed-plate gas-cooler was proposed to promote tank stratification and to improve system performance. The performance was evaluated through a series of experimental sensitivity and static tank charge tests. A TRNSYS model was also created and verified to simulate the performance of the system under a detailed user demand schedule for a week of operation. The TRNSYS model used a parametric table created with a steady-state model of the vapour-compression system in EES that was validated against experimental data to a standard error of the Y-estimate of ±0.073 kW for heating capacity, ±1.01°C for gas-cooler exit temperature, and ±0.086 for COP. A series of tank charge tests were conducted under thermosyphon flow and forced flow rates at 1 L/min, 2 L/min, and 4 L/min. The thermosyphon charge test produced the highest level of stratification and a total COP of 3 at an average flow rate of 0.73 L/min. All of the forced convection cases operated with a higher degree of mixing. TRNSYS model simulations with hot water draws found that the thermosyphon flow configuration performed with a higher degree of stratification under regular user demand while simulations with high flow rates resulted in a mixed tank at a high temperature. Results predicted an 11% reduction in required heat energy input to the storage, a 30% reduction in electrical energy consumption, a 35% reduction in heat loss, and a 29% improvement in COP for the thermosyphon test as compared to the operation with a mixed tank at 4 L/min. The thermosyphon draw test also performed with the lowest average tank temperature, yet produced the highest draw temperatures. Through these results, it was concluded that natural convection operation with brazed-plate gas-coolers can contribute to a better performing system and this flow configuration should be considered in future applications of this technology.

Degree

thesis:*
Department dc:contributor.department
Mechanical and Materials Engineering
Grantor
Queen's University at Kingston
Year dc:date.issued
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Murray, Portia
Advisor dc:contributor.supervisor
  • Harrison, Stephen J.

Subjects

dc:subject × 3

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1974/12681

Chain of custody

source
Harvested from
Queens University
Base URL
qspace.library.queensu.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Murray, Portia. Performance Analysis of a Transcritical CO2 Heat Pump Water Heater Incorporating a Brazed-Plate Gas-cooler. Queen's University at Kingston, 2015. https://hdl.handle.net/1974/12681