Back to search

Queen's University at Kingston

The White Beam Steady-State Diffractometer: A Next Generation Neutron Diffraction Strain Scanner

Abstract

dc:description.abstract

This project proposes a reactor-based instrument, which retains most of the above advantages of spallation source engineering instruments, while maintaining the advantages inherent to steady-state instruments. The main idea is to allow the entire white beam from the reactor onto the sample---no monochromation. Diffraction is then allowed at a fixed angle, and information from two sample directions can be obtained simultaneously. Since a white beam is incident onto the sample, the diffraction condition is satisfied for multiple sample planes in the fixed angle of diffraction. Multiple analyzer/detector pairs are placed downstream from the sample and tuned to scatter only one of the diffracted wavelength bands. Monte Carlo methods were used to create models of both a standard two-axis engineering diffractometer, found on current reactor sources, and the proposed white beam instrument. There models were validated by experiments performed on a standard two-axis instrument, which was also modified to operate in a white beam configuration, in which the position of the sample and monochromator were interchanged. Both the models and the experiments of the white beam instrument showed proof of concept for this design and identified areas of concern that required special attention. Upon a comparison on the results from the standard two-axis instrument to the results from the white beam instrument (both simulation and experimental), it was found that the standard diffractometer showed a better performance in all aspects. However, this project proposes numerous areas where the white beam design can be improved upon in order to enhance its performance as an engineering instrument. The most important of these is the design of an appropriate analyzer/detector system, as the results overwhelmingly show this to be the area of greatest concern. Ideas for a few such designs are also given.

Degree

thesis:*
Department dc:contributor.department
Physics, Engineering Physics and Astronomy
Grantor
Queen's University at Kingston
Year dc:date.issued
2009

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Percival, Aaron
Advisor dc:contributor.supervisor
  • Clapham, Lynann

Subjects

dc:subject × 7

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1974/1783

Chain of custody

source
Harvested from
Queens University
Base URL
qspace.library.queensu.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Percival, Aaron. The White Beam Steady-State Diffractometer: A Next Generation Neutron Diffraction Strain Scanner. Queen's University at Kingston, 2009. https://hdl.handle.net/1974/1783