A System For Computer-Assisted Surgery With Intraoperative CT Imaging

Abstract

dc:description.abstract

Image-guided interventions using intraoperative three-dimensional (3D) imaging can be less cumbersome than systems dependent on preoperative images, especially by needing neither image-to-patient registration nor a lengthy process of segmenting and generating a 3D model. In this dissertation, a method for computer-assisted surgery using direct navigation on intraoperative images is presented. In this system the registration step of a navigated procedure was divided into two stages: preoperative calibration of images to a ceiling-mounted optical tracking system, and intraoperative tracking during acquisition of the 3D image. The preoperative stage used a custom-made multi-modal calibrator that could be optically tracked and also contained fiducial spheres for radiological detection; a robust registration algorithm was used to compensate for the high false-detection rate that arose from the optical light-emitting diodes. Intraoperatively, a tracking device was at- tached to bone models that were also instrumented with radio-opaque spheres; a calibrated pointer was used to contact the latter spheres as a validation. The fiducial registration error of the calibration stage was approximately 0.1 mm with the Innova 3D X-ray fluoroscope and 0.7 mm with the mobile-gantry CT scanner. The target registration error in the valida- tion stage was approximately 1.2 mm with the Innova 3D X-ray fluoroscope and 1.8 mm with the mobile-gantry CT scanner. These findings suggest that direct registration can be a highly accurate means of performing image-guided interventions in a fast, simple manner.

Degree

thesis:*
Department dc:contributor.department
Computing
Grantor
Queen's University at Kingston
Year dc:date.issued
2009

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Oentoro, Anton
Advisor dc:contributor.supervisor
  • Ellis, Randy E.

Subjects

dc:subject × 2

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1974/2603

Chain of custody

source
Harvested from
Queens University
Base URL
qspace.library.queensu.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Oentoro, Anton. A System For Computer-Assisted Surgery With Intraoperative CT Imaging. Queen's University at Kingston, 2009. https://hdl.handle.net/1974/2603