Back to search

Queen's University at Kingston

Effect of Coating Defect, Desiccation, and Freeze-Thaw Cycles on Geosynthetic Clay Liner (GCLS) – Geomembrane Interface Transmissivity

Abstract

dc:description.abstract

A series of laboratory tests were conducted to investigate the effect of prehydration fluid, a 4-mm diameter central coating defect, coating defect position and nature, and the effect of coating orientation of a multi-component coated geosynthetic clay liner (GCL) on interface transmissivity, θ between the interfaces of GCL and a 1.5mm thick high-density polyethylene geomembrane (GMB) when permeated with a simulated municipal solid waste landfill leachate. Also, two different conventional GCLs were used to explore the effect of prehydration and permeant fluid, desiccation of GCL on θ and assess the self-healing capacity of desiccated GCLs for three different permeant solutions under a range of applied stresses (10-150 kPa). It was found that < 70 kPa, θ was dominated by variability in initial contact condition between the interfaces of GMB-GCL and the effect of other factors was largely masked by the contact variability. At 100-150 kPa the effects of initial variability were largely eliminated but there was no notable effect of other factors for both multi-component and conventional GCLs. Desiccation of GCLs increased transmissivity by up to three orders of magnitude compared to an intact specimen at 10-100 kPa. Even at 150 kPa desiccated specimens had θ ≤ 8.0x10-9 m2/s for all specimens tested. The chemical composition of permeant solutions, crack width, and nature of bentonite played an important role in healing the cracks of desiccated GCLs. A new laboratory test setup was developed to apply freeze-thaw cycles at the GMB-GCL interfaces and tests were conducted to do a preliminary study of 5 and 16 freeze-thaw cycles effect, two different prehydration fluids and means of hydration of GCL during freeze-thaw cycles on θ, for a range of stresses (10-100kPa). The preliminary results showed that the new test setup successfully applied freeze/thaw cycles to the interfaces of GMB/GCL. The ice lenses, on thawing had a significant effect on θ at 10 kPa. When GCLs were externally prehydrated with RO water and pore water and then subjected to freeze-thaw cycles, there was no evidence of any significant effect of 5-freeze/thaw cycles but there was an effect of 16 freeze/thaw cycles on interface transmissivity.

Degree

thesis:*
Department dc:contributor.department
Civil Engineering
Grantor
Queen's University at Kingston

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Jabin, Farhana
Advisor dc:contributor.supervisor
  • Rowe, Kerry

Subjects

dc:subject × 7

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1974/27660

Chain of custody

source
Harvested from
Queens University
Base URL
qspace.library.queensu.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Jabin, Farhana. Effect of Coating Defect, Desiccation, and Freeze-Thaw Cycles on Geosynthetic Clay Liner (GCLS) – Geomembrane Interface Transmissivity. Queen's University at Kingston, https://hdl.handle.net/1974/27660