Back to search

Queen's University at Kingston

SPR STUDIES OF N-HETEROCYCLIC CARBENE ADSORPTION KINETICS AND THE APPLICATION OF FIBER FABRY-PÉROT CAVITIES IN CHEMISTRY

Abstract

dc:description.abstract

Thiol self-assembling monolayers (SAMs) on metal surfaces are a key component of many optical biosensors. The discovery that N-heterocyclic carbenes (NHC) form higher-stability SAMs has sparked a wave of exploratory studies and applications. There are still many unknowns surrounding NHC SAM formation, including the adsorption kinetics and overall mechanism. A lab-built surface plasmon resonance (SPR) spectrometer was used to measure the NHC – gold adsorption kinetics of three NHC species. The spectrometer is described in Chapter 3. Solutions were introduced to a prism-mounted gold film via PDMS microfluidics. A camera then collected reflected light from the prism over a range of angles. At one angle (θSPR), the reflected light intensity was the dimmest. θSPR changes with the surface refractive index and was collected over time. In Chapter 4, the SAM formation rate constants for three (diisopropyl)benzimidazolium NHCs in methanol are presented and compared. When introduced in a similar way, bicarbonate NHC salts formed monolayers faster than triflate salts. In Chapter 5, several electrochemical methods are explored to remove NHCs from gold. Desorption efficacy was tested using cyclic voltammetry and X-ray photoelectron spectroscopy. Applying reductive potentials in base led to significant NHC desorption. Oxidative potentials also led to limited NHC desorption via surface corrosion. A prototypical SPR-electrode chip was also presented and tested. Fiber Fabry-Perot (FFP) cavities are optical strain sensors that work by locking to a cavity resonance fringe. In Chapter 6, an FFP is used to measure dye concentrations by way of photoacoustic spectroscopy. A wineglass is used as the sample holder and acoustic resonator, with the FFP attached to its rim. A modulated laser excites the dye solution, generating an acoustic wave that is amplified by the wineglass and detected by the FFP. Both methyl red and (phospho)molybdenum blue were quantified using the technique. In Chapter 7, the same FFP cavity was used for in-line viscosity and density measurements using an attached vibrating cantilever. While immersed in liquid, the cantilever’s resonance peak shape was collected and used to infer the liquid’s viscosity and density. The technique was demonstrated for several consumer beverages.

Degree

thesis:*
Department dc:contributor.department
Chemistry
Grantor
Queen's University at Kingston

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • MacLean, Amy
Advisors dc:contributor.supervisor
  • Loock, Hans-Peter
  • Escobedo, Carlos

Subjects

dc:subject × 23

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1974/29822

Chain of custody

source
Harvested from
Queens University
Base URL
qspace.library.queensu.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

MacLean, Amy. SPR STUDIES OF N-HETEROCYCLIC CARBENE ADSORPTION KINETICS AND THE APPLICATION OF FIBER FABRY-PÉROT CAVITIES IN CHEMISTRY. Queen's University at Kingston, https://hdl.handle.net/1974/29822