dc:description.abstract

Ultra-high-performance fiber reinforced concrete (UHPFRC) has been investigated as a wythe material in insulated double wythe precast concrete (DWPC) panels resulting in thin lightweight wythes while still satisfying structural, thermal, and architectural requirements. However, the connection between the panels and a building frame have not been studied yet. This thesis includes 230 experimental tests investigating the pull-out and shear performance, in accordance with ASTM E488-18, of screw anchors and novel threaded rod connector embedded in thin UHPFRC members, containing polyvinyl alcohol (PVA) fibers. The pull-out study examines the effects of slab thickness (tc), connector diameter (d), fiber percentage in UHPFRC (pf), embedment depth (hef), support ring diameter (ds) of the slab and concrete compressive strength (f’c). The threaded rod outperformed the screw anchor with ultimate pull-out loads (Pu) that were 20-50% larger. Increasing hef from 0.75tc to 1.0tc increased Pu by 19-67% for the screw anchor. Increasing tc from 15 to 38 mm, with 1.0tc embedment, resulted in Pu to be on average over 3.5 and over 4 times greater for the screw anchor and threaded rod, respectively. Results showed that d, pf, and ds did not have significant effect on Pu. ACI 318-19 and Tarawneh et. al. (2020) design equations grossly overestimated Pu of the connectors. New design equations are proposed based on regression analysis. A design example was presented to determine if the connectors can satisfy pull-out design requirements. The shear study examines the effects of slab thickness (tc), connector diameter (d), fiber percentage (pf) in UHPFRC, edge distance (c1), and support span length (ls). The threaded rod outperformed the screw anchor with ultimate shear loads (Vu) that were 29-93% larger. Increasing c1 had significant effect on Vu, where it was over two times greater when c1 was increased from 38 to 89 mm. Increasing tc from 25 to 38 mm resulted in Vu increasing by 24-43% for the screw anchor, while for the threaded rod, Vu increased by 1.3-3.3 times when tc increased from 15 to 38 mm. Results showed that d, pf, and ls did not have significant effect on Vu. ACI 318-19 and Tarawneh et. al. (2020) design equations grossly overestimated Vu of the connectors. New design equations are proposed based on regression analysis. A design example was presented to account for combined pull-out and shear forces in design.

Degree

thesis:*
Department dc:contributor.department
Civil Engineering
Grantor
Queen's University at Kingston

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Prejs, Andy
Advisor dc:contributor.supervisor
  • Prejs, Andy

Subjects

dc:subject × 7

Rights

dc:rights
Statement dc:rights
  • CC0 1.0 Universal
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1974/30066

Chain of custody

source
Harvested from
Queens University
Base URL
qspace.library.queensu.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Prejs, Andy. Behavior and Design of Post-Installed Connectors in Thin Ultra-High Performance Fiber Reinforced Concrete Members. Queen's University at Kingston, https://hdl.handle.net/1974/30066