Back to search

Queen's University at Kingston

Multi-component mass transfer of background dissolved gases and stray methane gas in shallow groundwater systems

Abstract

dc:description.abstract

The goal of this research was to investigate the effects of multi-component mass transfer between methane gas and background dissolved gases (e.g., nitrogen) to improve stray gas detection techniques and advance understanding of methane persistence following a repaired leak. This was achieved by conducting a series of gas injection experiments in a quasi-two-dimensional flow cell (40 × 39.6 × 1.15 cm) simulating an active gas leak and a post-repair scenario and developing simple single cell numerical models of the active (steady-state) leak and the post-repair (kinetic) dissolution. Experiments were conducted at two aqueous fluxes (3.8 m/day and 0.9 m/day) and two heterogeneities (pool- and finger-dominated source architectures). Dissolved oxygen was measured in the effluent water as a representative of background dissolved gases and light transmission techniques were used to quantify gas saturations. A steady-state model was developed to predict the mass transfer rate coefficient for each experiment and the changes in background dissolved gases under a range of conditions. A kinetic model was developed to predict the gas saturations and dissolved gas concentrations during post-repair dissolution, testing the sensitivity of mass transfer rate coefficients and single- and multi-component dissolved gases. Experiments showed that background dissolved gas detectability was highest at slow groundwater fluxes and in pooled source architectures. The steady-state model indicated that the detectability of background dissolved gases was proportional to the initial background dissolved gas concentration in the groundwater, however, the dissolved source gas concentrations remained relatively unchanged with depleted background dissolved gases. Experiments also showed that more time was required for background dissolved gases to return to baseline conditions post repair in pooled source architectures. Kinetic model simulations indicated that a constant mass transfer rate coefficient was sufficient to predict experimental data, as a transient mass transfer rate coefficient did not substantially improve the model fit. The kinetic model also demonstrated that gas persistence was longer in simulations that considered multiple dissolved gases compared to a single-component model. The findings of this study indicate that background dissolved gases may be a useful tool for stray gas detection and that gas persistence is influenced by multiple dissolved gases.

Degree

thesis:*
Department dc:contributor.department
Civil Engineering
Grantor
Queen's University at Kingston

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Calvert, Madeline
Advisor dc:contributor.supervisor
  • Mumford, Kevin

Subjects

dc:subject × 5

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1974/30485

Chain of custody

source
Harvested from
Queens University
Base URL
qspace.library.queensu.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Calvert, Madeline. Multi-component mass transfer of background dissolved gases and stray methane gas in shallow groundwater systems. Queen's University at Kingston, https://hdl.handle.net/1974/30485