Back to search

Queen's University at Kingston

Fire Performance of Ultra-High Performance Concrete Double-Wythe Insulated Panels

Abstract

dc:description.abstract

Ultra-High Performance Concrete (UHPC) is emerging as an alternative material to conventional normal strength concrete in structural applications including bridges, buildings, and structural strengthening and retrofitting. Adoption of UHPC is limited by its relatively poor performance in fire conditions, a result of its propensity for explosive spalling. Additionally, a lack of formal fire standards and ratings adopted by national building codes for the use of UHPC in structural applications is a deterrent to its adoption. In an effort to enhance the use of UHPC, this thesis presents the results from a large research study on the behaviour of UHPC in fire, with a focus on UHPC double-wythe insulate (DWI) panels. The research study has four major subsections; material characterization under elevated temperatures, small-scale testing under a standard fire, intermediate-scale testing under a standard fire, and numerical modelling. Material characterization, specifically compressive and direct tensile strength tests, are performed on four types of UHPC, which vary by the percentage of synthetic fibres included in their mix design. Small-scale fire tests are performed on two sets of UHPC DWI panels to gain a preliminary understanding on their performance under a standard fire. Single UHPC wythes are also tested under a standard fire to isolate and understand thermal bowing in UHPC. Intermediate-scale fire tests are performed on two sets of UHPC DWI panels to characterize their thermal performance under requirements set by Canadian national building codes. A thermal and structural finite element (FE) numerical model for UHPC DWI panels are developed and verified separately. The thermal model is validated with results from the intermediate-scale fire tests and the structural model is verified with results found in the literature. The models are developed such that future research can combine the thermal and structural analysis to estimate the fire resistance of UHPC DWI panels. This thesis illustrates that conventional UHPC DWI panels are capable of meeting the temperature criteria for fire ratings, however visual observations show that they are unlikely to meet the structural capacity requirements to achieve a satisfactory fire rating.

Degree

thesis:*
Department dc:contributor.department
Civil Engineering
Grantor
Queen's University at Kingston
Year dc:date.issued
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • MacDougall, Branna
Advisor dc:contributor.supervisor
  • Green, Mark

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • Attribution 4.0 International
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1974/34233

Chain of custody

source
Harvested from
Queens University
Base URL
qspace.library.queensu.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

MacDougall, Branna. Fire Performance of Ultra-High Performance Concrete Double-Wythe Insulated Panels. Queen's University at Kingston, 2024. https://hdl.handle.net/1974/34233