dc:description.abstractThis thesis investigates the experimental breakup of single "mother" bubbles into smaller "daughter" bubbles by means of applying a multi-frequency acoustic (sound) field. This work was motivated by the negative side-effects gaseous bubbles have in the circulatory system following open-heart surgery. Gaseous emboli (bubbles) arise in open-heart surgery from trapped gases within the heart. These gas bubbles can get lodged in the circulatory system and reduce or even stop blood flow. Blockages are of most concern in the brain, where blood vessels are small and blockages can cause neurological damage. This thesis proposes a potential solution to reduce neurological impairment from these large gaseous emboli. Acoustic excitation of initially larger "mother" bubbles was used to break them up into smaller "daughter" bubbles, which should have a smaller neurological impact. Experimental observation was conducted on the effectiveness of subjecting a mother bubble to three acoustic sound profiles, specifically, single frequency, pulsed single frequency and sweep frequency. The sound profile should be a combination of a pulsed and sweep frequency sound: the pulses to induce larger breakups following re-excitation (type B breakup), and the sweep frequency to follow the natural frequency and guarantee type C breakup thereafter. Another outcome in this thesis was the introduction of type A, B and C breakup subcategories, which were related to bubble symmetry upon acoustic excitation. These subcategories of non-inertial cavitation are formally defined within this thesis and revealed through experimental observation. In addition, a software algorithm was designed and built to identify and measure gaseous emboli during deaeration. The software was appropriately named Detection of Emboli using Transesophageal Echocardiography for Counting, Total volume and Size estimation (DETECTS). DETECTS uses existing ultrasound technology to quantify the amount of gaseous emboli that leave the heart. DETECTS could allow surgeons to validate the effectiveness of current and future deaeration techniques following open-heart surgery. The validation of the DETECTS software used optical methods to correlate air bubble size and location in vitro.
Degree
thesis:*- Department dc:contributor.department
- Mechanical and Materials Engineering
- Grantor
- Queen's University at Kingston
- Year dc:date.issued
- 2025
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Secretain, Frank
- Advisor dc:contributor.supervisor
-
- Pollard, Andrew
Subjects
dc:subject × 5Rights
dc:rights- Statement dc:rights
-
- Attribution 4.0 International
- Licence dc:rights.uri
- Language dc:language.iso
- eng
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/1974/34259