Abstract
dc:description.abstractDifferential ground movements can impose stresses along buried pipes and cause ruptures or joint openings. The presence of joints (e.g., fusion welds) and branched pipes (e.g., service connections) can act as anchors, increasing pipe stresses and potentially influencing the bending response of pipes subjected to differential ground movements. This study presents the results from four large-scale pullout experiments with distributed fibre optic sensing (DFOS), which were conducted to investigate the axial resistance of fusible polyvinyl chloride (FPVC) pipes and the restraint provided by fusion weld joints and service connections. The results showed that the pullout resistance of plain FPVC pipes in dense sand was underpredicted by seismic design guidelines by 46%, while the inclusion of a fusion weld increased the resistance by 6%, and the two service connections increased the resistance by 71%. Using the experimental data, a new technique was developed to derive empirical axial soil-springs from DFOS strain data. Beyond axial pullout behaviour, the study presents results from three large-scale experiments conducted to investigate the influence of axial restraint and pretension on the bending response of buried FPVC pipes crossing a normal fault. While the experimental results showed that axial restraint and pretension had a negligible effect on the peak bending response of the tested FPVC pipe for fault offsets up to one pipe diameter, numerical modelling results indicated that a steel pipe of the same diameter was more sensitive to axial restraint. At a fault offset of two pipe diameters, axial restraint of the modelled steel pipe caused a 10% reduction in peak bending strain. Fibre optic cables buried adjacent to the pipe during a simulated normal fault experiment showed potential for detecting the location of normal faults. However, single fibre optic cables had inherent limitations that were addressed using a novel DFOS strip sensor, which measured soil settlements within 5% of digital image correlation (DIC) measurements. Finally, based on limitations encountered in this study, the design of a new vertical ground deformation facility capable of producing a versatile set of differential settlement patterns using a novel moving floor system is presented.
Degree
thesis:*- Department dc:contributor.department
- Civil Engineering
- Grantor
- Queen's University at Kingston
- Year dc:date.issued
- 2025
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Matymish, Jonathan Michael
- Advisors dc:contributor.supervisor
-
- Moore, Ian
- Hoult, Neil
- Woods, Joshua
Subjects
dc:subject × 4Rights
- Language dc:language.iso
- eng
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/1974/35310