Queen's University at Kingston
Investigation of RC Columns Encased in UHPC Tubes Under Axial Load and Bending Including Assessments of Interfacial Bond and Tube Properties
Abstract
dc:description.abstractThis thesis investigates the behavior of composite columns consisting of reinforced normal-strength concrete (NSC) cores cast into ultra-high-performance concrete (UHPC) stay-in-place tubular forms with a novel corrugated interface. The axial load-bending moment (P-M) interaction curve is developed experimentally, analytically, and numerically. The interfacial bond between the two materials is studied under a wide range of extreme temperatures, comparing various surface textures. The behavior of the UHPC tube under hoop tension arising from NSC core dilation is studied using the split-disk test, while its behavior under transverse compression is also examined using the parallel-plates test for other potential applications, such as buried pipes. Different fiber types and dosages, as well as steel mesh reinforcement ratios, were explored for the UHPC tube. Concentrically loaded columns demonstrated that UHPC tubes significantly enhanced axial capacity; however, this improvement is attributed mainly to the axial load contribution of the tube rather than confinement of the NSC core. The tube is subjected to a biaxial stress state, reducing both its hoop and axial strengths at failure. Eccentrically loaded columns reveal that UHPC contribution is most pronounced in the compression-controlled region of the P-M interaction diagram. Reducing the tube diameter-to-thickness (Dₒ/tᵤ) ratio from 25 to 15 and then to 7 increased the area enclosed by the normalized (P/Do2-M/Do3) curve by 22% and 57%, respectively, demonstrating the level of UHPC contribution as a function of column size for the same thickness. The corrugated interface enhanced flexural strength by up to 29% compared to a smooth interface. The bond-slip behavior between UHPC and NSC is examined through push-out testing. Peak bond strength (τᵤ) was highly sensitive to temperature, surface texture, fiber type, and NSC compressive strength. Due to thermally induced pressure on the NSC core, τᵤ doubled at -20°C. Bubble-textured UHPC surfaces were compared to corrugations. Relative to a smooth interface, the former achieved up to a 119% increase in τᵤ, while the latter achieved up to a 78% increase. Finally, a calibration of ABAQUS concrete damage plasticity (CDP) model parameters was conducted for UHPC, and modification factors to the post-peak tensile stress-strain response were introduced.
Degree
thesis:*- Department dc:contributor.department
- Civil Engineering
- Grantor
- Queen's University at Kingston
- Year dc:date.issued
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Fakeh, Mina Fathi Abadir
- Advisor dc:contributor.supervisor
-
- Fam, Amir
Subjects
dc:subject × 5Rights
- Language dc:language.iso
- eng
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/1974/36061