Queen's University at Kingston
Differential Geometric Control of Three-phase Solar Microinverters based on Lie Groups
Abstract
dc:description.abstractSolar microinverters enable module-level power conditioning and are a key technology for distributed PV generation. To improve system lifetime and reliability, large electrolytic DC link capacitors are increasingly being replaced with small film capacitors. However, the usage of a small DC link capacitor significantly reduces the available energy buffer, placing greater demands on the control scheme to maintain robust transient performance during disturbances. The control architecture of the inverter stage is typically implemented either in the abc frame, the stationary αβ frame, or the synchronous dq frame. Although these conventional approaches provide good steady-state performance, their transient response can deteriorate under large disturbances, leading to suboptimal control trajectories, increased overshoot, and longer settling times. These limitations become more pronounced when the DC link is not stiff, since DC link dynamics can couple with AC-side transients and further degrade overall performance. This thesis proposes a new differential-geometric control framework for three-phase solar microinverters based on Lie groups. Since three-phase voltages and currents are inherently periodic and evolve on rotation manifolds, Lie groups provide a natural framework for modeling their dynamics. By formulating the system on Lie groups such as SO(2) and SE(2), globally defined, coordinate-invariant error measures can be constructed on the manifold. Control laws are then derived directly on the associated Lie algebras to steer the system on the manifold, yielding improved transient performance with good steady-state tracking. The proposed framework is first applied to a grid-tied microinverter, where inverter current control is posed as a tracking problem on the SE(2) Lie group. This geometric formulation enables fast, coordinate-invariant tracking under grid disturbances and DC link power variations by exploiting all available control degrees of freedom. The framework is then extended to standalone solar-fed motor drives, where vector-control strategies such as maximum-torque-per-ampere (MTPA) operation are formulated on the SO(2) and SE(2) Lie groups. The resulting control laws enable reliable operation of the drive without position sensors, ensuring stable DC link dynamics during start-up and under input-power and load transients. Simulation and experimental results validate the proposed methods, demonstrating improved transient performance and reliable operation of microinverters with small DC link capacitance.
Degree
thesis:*- Department dc:contributor.department
- Electrical and Computer Engineering
- Grantor
- Queen's University at Kingston
- Year dc:date.issued
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Kalathy, Abirami
- Advisors dc:contributor.supervisor
-
- Pahlevani, Majid
- Jain, Praveen
Subjects
dc:subject × 9Rights
dc:rights- Statement dc:rights
-
- Attribution-NonCommercial-NoDerivatives 4.0 International
- Licence dc:rights.uri
- Language dc:language.iso
- eng
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/1974/36192