Back to search

Queen's University at Kingston

Structural Behaviour of Pre-Engineered Beam-Hanger Connections for Mass Timber and Hybrid Mass Timber-Steel Structures

Abstract

dc:description.abstract

The strength of connections in mass timber structures is critical to ensuring structural safety. The connections between beams and columns in modern mass timber construction are often facilitated using pre-engineered beam-hanger connections, which consist of interlocking metal brackets that are fastened to the timber elements using self-tapping screws. While these connections are relied upon to transfer shear, they must also have sufficient rotational capacity to withstand a design-level earthquake without losing their load-carrying capacity. This research investigates the rotational capacity of three commonly used pre-engineered beam-column connections, including a bolt and collar, an interlocking jaw, and a tongue and pocket connection style. The influence of several parameters on the cyclic performance of the connectors was investigated, including the influence of gravity load, screw configuration, timber-steel beam-columns, and the installation of two connectors side-by-side. Results of the study demonstrate that the bolt and collar, and tongue and pocket connections consistently achieved maximum rotational capacity beyond 0.06 rad prior to losing their load carrying capacity while the interlocking jaw connections achieved rotations above 0.08 rad. Ultimately, all the tested connections met the rotation required to meet North American lateral drift limits. Despite the widespread use of pre-engineered beam-hangers in practice, questions remain surrounding how to predict the strength of self-tapping screw connections installed in the end grain of a glulam beam. This research additionally aims to address this knowledge gap and presents the results of 78 connection tests, including connections with varying installation depth, wood species, and standardized test methods used in North America and Europe. The experimental test results show that the effective depth of the connection has a significant influence on its strength and failure mode. A comparison with existing design provisions demonstrated that the Canadian CSA O86:24 standard can be used to accurately predict the splitting strength of connections made with shear screws installed in the end grain or with combined shear and inclined screws installed in the end grain, with average predicted-to-test ratios of 1.05 (COV = 0.10) and 0.95 (0.05), respectively.

Degree

thesis:*
Department dc:contributor.department
Civil Engineering
Grantor
Queen's University at Kingston
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Wierzbowski, Andrew W.
Advisor dc:contributor.supervisor
  • Woods, Joshua

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivatives 4.0 International
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1974/36325

Chain of custody

source
Harvested from
Queens University
Base URL
qspace.library.queensu.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Wierzbowski, Andrew W.. Structural Behaviour of Pre-Engineered Beam-Hanger Connections for Mass Timber and Hybrid Mass Timber-Steel Structures. Queen's University at Kingston, 2026. https://hdl.handle.net/1974/36325