Back to search

Queen's University at Kingston

Deflagration-to-Detonation Transition (DDT) for Methane-Hydrogen-Oxygen Mixtures in a Round Tube

Abstract

dc:description.abstract

Experiments were performed to investigate flame acceleration and DDT in a long smooth polycarbonate tube with a 5.08-cm inner diameter for hydrogen-methane-oxygen mixtures. Test pressures ranged from 15-31 kPa; the upper limit being constrained by the strength of the tube. The main diagnostic was high speed photography. In all cases the flame accelerated to above the speed of sound in the combustion products and then transitioned to detonation. The transition to detonation was identified on video by the appearance of a bright hot spot, and thus the DDT run-up distance (XDDT) could accurately be measured via video. For higher methane content mixture (<50% H2) the run-up distance did not noticeably change with increasing hydrogen content. For higher hydrogen content mixtures, scatter in run-up distance data increased, which for 75% hydrogen was due to three DDT mechanisms, and for 100% hydrogen, DDT was observed for pressures greater than 25 kPa due to the interaction between the flame and the reflected shock wave promoting flame acceleration and DDT. No DDT was observed for 100% hydrogen without a reflected shock interaction, indicating that in a longer tube, hydrogen would have the longest run-up distance. For 100% hydrogen the distance for the flame to accelerate form the speed of sound in the products to DDT, i.e., XDDT - XF, was found to be 20% of XDDT, compared to 40% for the other mixtures. Early flame propagation was responsible for the large XDDT. In a second experiment, DDT from a fast flame, generated by passing a detonation through a perforated plate, was investigated in a 7.62-cm diameter tube. This experiment aimed to remove the effects of initial flame acceleration on DDT, focusing on the flame behaviour from below the products speed of sound, to the onset of DDT. DDT induction distance measured in this experiment can be compared to XDDT - XF from the traditional DDT experiment. This experiment showed three distinct mechanisms for DDT with three distinct ranges of DDT induction distances, where increasing hydrogen content resulted in longer induction distances. For 100% hydrogen no DDT was observed in the length of the tube.

Degree

thesis:*
Department dc:contributor.department
Mechanical and Materials Engineering
Grantor
Queen's University at Kingston
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Elia, Thomas
Advisor dc:contributor.supervisor
  • Ciccarelli, Gabriel

Subjects

dc:subject × 2

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1974/36430

Chain of custody

source
Harvested from
Queens University
Base URL
qspace.library.queensu.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Elia, Thomas. Deflagration-to-Detonation Transition (DDT) for Methane-Hydrogen-Oxygen Mixtures in a Round Tube. Queen's University at Kingston, 2026. https://hdl.handle.net/1974/36430